OSHA Inspection: ISLAND RENTALS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ISLAND RENTALS in NEW COMMERCIAL BUILDING, MAIN ROAD, NU'ULI ACROSS FROM LAUFOU SHOPPING CENTER, PAGO PAGO, AS 96799 (NAICS 238120). OSHA activity number 340529189.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Island Rentals — free Get an email when a new federal OSHA severe-injury report for Island Rentals is published. One employer, no account, unsubscribe in one click.
Establishment
ISLAND RENTALS
Site address
NEW COMMERCIAL BUILDING, MAIN ROAD, NU'ULI ACROSS FROM LAUFOU SHOPPING CENTER
City
PAGO PAGO
State
AS
ZIP
96799
Mailing
P.O. BOX 2316, PAGO PAGO, AS 96799
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 2 instances 4 exposed
Issued
May 6, 2015
Penalty
Initial $1,224 · Current $857 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a. On April 2, 2015, on the first floor, employees were not wearing hard hats below those working above them, exposing themselves to an overhead hazard.
Recent events (2)
  • — I (S) $856.8
  • — Z (S) $1224

1926.403 B02

Serious Gravity 5 2 instances 4 exposed
Issued
May 6, 2015
Penalty
Initial $1,224 · Current $857 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:   a. On April 2, 2015, the junction box outlet connected to extension cord and lying on the ground was not installed correctly, exposing the employees to an electrical hazard.
Recent events (2)
  • — I (S) $856.8
  • — Z (S) $1224

1926.405 B02

Serious Gravity 5 2 instances 4 exposed
Issued
May 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers:  a. On April 2, 2015, the junction box outlet connected to extension cord lying on the ground did not have a cover, exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 6, 2015
Penalty
Initial $1,224 · Current $857 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  a. On April 2, 2015, the portable drill did not have a ground fault circuit interrupter (GFCI), exposing employees to an electrical hazard.
Recent events (2)
  • — I (S) $856.8
  • — Z (S) $1224

1926.1052 C01

Serious Gravity 5 1 instance 4 exposed
Issued
May 6, 2015
Penalty
Initial $1,224 · Current $857 Reduced
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge:  a. On April 2, 2015, an exterior stairways from the 1st to 2nd floors were not equipped with at least one hand rail and a stairrail system along each unprotected side, exposing the employees to fall hazards.
Recent events (2)
  • — I (S) $856.8
  • — Z (S) $1224

1926.405 G02 IV

Other-than-serious 2 instances 4 exposed
Issued
May 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  a. On April 2, 2015, on the 2nd floor, the electrical cord receptacle was not connected in a manner that strain relief was provided.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0