Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAL-MAINE FOODS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CAL-MAINE FOODS, INC. in 1039 ZUMBRUM RD., UNION CITY, OH 45390 (NAICS 112310). OSHA activity number 340535038.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cal-Maine Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Cal-Maine Foods, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1039 ZUMBRUM RD.
City
UNION CITY
State
OH
ZIP
45390
Mailing
1039 ZUMBRUM RD., UNION CITY, OH 45390
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112310
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.23 E02

Serious Gravity 5 1 instance 6 exposed
Issued
May 5, 2015
Abate by
Jun 8, 2015
Penalty
Initial $3,400 · Current $2,500 Reduced
29 CFR 1910.23(e)(2): A stair railing shall be of construction similar to a standard railing but the vertical height shall be not more than 34 inches nor less than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread.    On the front and rear wood platform on House #5, employees were exposed a fall hazard from the lack of an adequate stair railing due to the inadequate height of the top rail and the lack of a midrail on the open side of the stairs leading down from the platform to the ground.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3400

1910.23 E03 IV

Serious Gravity 10 1 instance 6 exposed
Issued
May 5, 2015
Abate by
Jun 8, 2015
Penalty
Initial $7,000 · Current $2,700 Reduced
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types shall be of such construction that the completed structure shall be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail.      On or about April 5, 2015, at House #5' rear platform, employees were exposed to an eight and one-half fall hazard due to an inadequate removable standard guardrail railing, 2x4 inch top rail and mid rail which were too short in length to provide the required strength requirements.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $7000

1910.24 F

Other-than-serious 1 instance 3 exposed
Issued
May 5, 2015
Abate by
May 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.24(f): "Stair treads." All treads shall be reasonably slip-resistant and the nosings shall be of nonslip finish. Welded bar grating treads without nosings are acceptable providing the leading edge can be readily identified by personnel descending the stairway and provided the tread is serrated or is of definite nonslip design. Rise height and tread width shall be uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs.  On the front and rear 12 wooden steps leading up to the wooden platform of House #5, employees were exposed to a fall hazard from the lack of a nonslip finish on the nosing of the wooden steps.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cal-Maine Foods, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340535038.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.