UNION CITY, OH —
OSHA Inspection: CAL-MAINE FOODS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CAL-MAINE FOODS, INC. in 1039 ZUMBRUM RD., UNION CITY, OH 45390 (NAICS 112310). OSHA activity number 340535038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAL-MAINE FOODS, INC.
- Site address
- 1039 ZUMBRUM RD.
- City
- UNION CITY
- State
- OH
- ZIP
- 45390
- Mailing
- 1039 ZUMBRUM RD., UNION CITY, OH 45390
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 112310
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 E02
- Issued
- May 5, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $3,400 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.23(e)(2): A stair railing shall be of construction similar to a standard railing but the vertical height shall be not more than 34 inches nor less than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread. On the front and rear wood platform on House #5, employees were exposed a fall hazard from the lack of an adequate stair railing due to the inadequate height of the top rail and the lack of a midrail on the open side of the stairs leading down from the platform to the ground. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $2500
- — Z (S) $3400
1910.23 E03 IV
- Issued
- May 5, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $7,000 · Current $2,700 Reduced
General-duty citation text
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types shall be of such construction that the completed structure shall be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail. On or about April 5, 2015, at House #5' rear platform, employees were exposed to an eight and one-half fall hazard due to an inadequate removable standard guardrail railing, 2x4 inch top rail and mid rail which were too short in length to provide the required strength requirements. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $2700
- — Z (S) $7000
1910.24 F
- Issued
- May 5, 2015
- Abate by
- May 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(f): "Stair treads." All treads shall be reasonably slip-resistant and the nosings shall be of nonslip finish. Welded bar grating treads without nosings are acceptable providing the leading edge can be readily identified by personnel descending the stairway and provided the tread is serrated or is of definite nonslip design. Rise height and tread width shall be uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs. On the front and rear 12 wooden steps leading up to the wooden platform of House #5, employees were exposed to a fall hazard from the lack of a nonslip finish on the nosing of the wooden steps. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET)
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cal-Maine Foods, INC.
View Cal-Maine Foods, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 112310)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340535038.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.