OSHA Inspection: J T REMODELING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of J T REMODELING LLC in 20-13 125TH STREET, COLLEGE POINT, NY 11356 (NAICS 236115). OSHA activity number 340535475.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J T Remodeling LLC — free Get an email when a new federal OSHA severe-injury report for J T Remodeling LLC is published. One employer, no account, unsubscribe in one click.
Establishment
J T REMODELING LLC
Site address
20-13 125TH STREET
City
COLLEGE POINT
State
NY
ZIP
11356
Mailing
94-37 86TH ROAD, WOODHAVEN, NY 11421
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
May 27, 2015
Abate by
Aug 5, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:      A.     On or about 04/10/15, at site 20-13 125th Street. College Point, NY       Employees working underneath of a pump jack scaffold were not provided with protective helmets.    ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
May 27, 2015
Abate by
Aug 5, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:                        *Insulated Lines    _____________________________________________________________________                                                      Voltage          Minimum distance           Alternatives  ____________________ ________________________ _______________________                                                 Less than 300 volts.  3 feet (0.9 m)            300 volts to 50 kv.  10 feet (3.1 m)           More than 50 kv.....  10 feet (3.1 m) plus     2 times the length                        0.4 inches (1.0 cm)      of the line                        for each 1 kv over       insulator, but never                        50 kv.                   less than 10                                                 feet (3.1 m).  ____________________ ________________________ _______________________                            *Uninsulated lines  _____________________________________________________________________                                                     Voltage           Minimum distance         Alternatives  ____________________ ________________________ _______________________                                                 Less than 50 kv.....  10 feet (3.1 m).          More than 50 kv.....  10 feet (3.1 m) plus     2 times the length of                        0.4 inches (1.0 cm)      the line insulator,                        for each 1 kv over       but never less than                        50 kv.                   10 feet (3.1 m).  ____________________ ________________________ _______________________    Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines:      A.     On or about 04/10/15, at site 20-13 125th Street. College Point, NY       Employees working on pump jack scaffold next to power lines less than 300 volts were exposed to electrical shock hazard.    ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
May 27, 2015
Abate by
Jun 2, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:      A.     On or about 04/10/15, at site 20-13 125th Street. College Point, NY       Employees working on an unprotected pump jack scaffold were exposed to the hazard of falling approximately 15 ft. to the concrete ground.    ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

View J T Remodeling LLC's full OSHA safety record →