COLLEGE POINT, NY —
OSHA Inspection: J T REMODELING LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J T REMODELING LLC in 20-13 125TH STREET, COLLEGE POINT, NY 11356 (NAICS 236115). OSHA activity number 340535475.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J T REMODELING LLC
- Site address
- 20-13 125TH STREET
- City
- COLLEGE POINT
- State
- NY
- ZIP
- 11356
- Mailing
- 94-37 86TH ROAD, WOODHAVEN, NY 11421
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- May 27, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A. On or about 04/10/15, at site 20-13 125th Street. College Point, NY Employees working underneath of a pump jack scaffold were not provided with protective helmets. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 F06
- Issued
- May 27, 2015
- Abate by
- Aug 5, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: *Insulated Lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 300 volts. 3 feet (0.9 m) 300 volts to 50 kv. 10 feet (3.1 m) More than 50 kv..... 10 feet (3.1 m) plus 2 times the length 0.4 inches (1.0 cm) of the line for each 1 kv over insulator, but never 50 kv. less than 10 feet (3.1 m). ____________________ ________________________ _______________________ *Uninsulated lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 50 kv..... 10 feet (3.1 m). More than 50 kv..... 10 feet (3.1 m) plus 2 times the length of 0.4 inches (1.0 cm) the line insulator, for each 1 kv over but never less than 50 kv. 10 feet (3.1 m). ____________________ ________________________ _______________________ Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines: A. On or about 04/10/15, at site 20-13 125th Street. College Point, NY Employees working on pump jack scaffold next to power lines less than 300 volts were exposed to electrical shock hazard. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 G01 VII
- Issued
- May 27, 2015
- Abate by
- Jun 2, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: A. On or about 04/10/15, at site 20-13 125th Street. College Point, NY Employees working on an unprotected pump jack scaffold were exposed to the hazard of falling approximately 15 ft. to the concrete ground. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections at J T Remodeling LLC
View J T Remodeling LLC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340535475.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.