Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN STEEL & PRECAST ERECTORS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AMERICAN STEEL & PRECAST ERECTORS in 194 SUMMER STREET, STAMFORD, CT 06901 (NAICS 238120). OSHA activity number 340551274.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Steel & Precast Erectors — free Get an email when a new federal OSHA severe-injury report for American Steel & Precast Erectors is published. One employer, no account, unsubscribe in one click.
Site address
194 SUMMER STREET
City
STAMFORD
State
CT
ZIP
06901
Mailing
328 SAWMILL ROAD, GREENFIELD, NH 03047
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
54
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 21, 2015
Abate by
Apr 27, 2015
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  Jobsite: The employees, engaged in construction activities from improperly elevated working positions, such as (but not limited to) standing on stepladder that was placed very close proximity from the steel wire guardrail and standing on top rail of the steel wire guardrail were not protected from the hazard of falling by the use of appropriate fall protection systems and/or devices.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1926.501 B12

Serious Gravity 5 3 instances 5 exposed
Issued
Apr 21, 2015
Abate by
Apr 27, 2015
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1926.501(b)(12): Each employee engaged in the erection of precast concrete members (including, but not limited to the erection of wall panels, columns, beams and floor and roof "tees") and related operations such as grouting of precast concrete members, who is 6 feet (1.8m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  Jobsite: The employees, who were in the process of setting the precast concrete members on the structural steel supports from the deck were not protected from the falling through open-sided deck by the use of appropriate fall protection systems and/or devices.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

View American Steel & Precast Erectors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340551274.