WARRENSVILLE HEIGHTS, OH ·
OSHA Inspection: STURGILL'S STUCCO, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STURGILL'S STUCCO, INC. in 4650 RICHMOND ROAD, WARRENSVILLE HEIGHTS, OH 44128 (NAICS 238990). OSHA activity number 340553817.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STURGILL'S STUCCO, INC.
- Site address
- 4650 RICHMOND ROAD
- City
- WARRENSVILLE HEIGHTS
- State
- OH
- ZIP
- 44128
- Mailing
- 41737 BIGGS RD, LAGRANGE, OH 44050
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 10
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.451 E01
- Issued
- May 12, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. On or about April 14, 2015, during plaster masonry activities the employer did not ensure employees working from a Waco brand fabricated frame type scaffold had a ladder or other safe means to access the working platforms of the scaffold, located approximately 16 feet above the ground. Employees and the foreman were climbing the ends and cross braces to access the working platforms of the scaffold.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
1926.451 G01
- Issued
- May 12, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about April 14, 2015, during plaster masonry activities the employer did not ensure employees working from a Waco brand fabricated frame type scaffold, located on the north side of the worksite, were protected from falling by a guardrail, personal fall arrest, or other fall protection system. The employee was working approximately 16 feet above the ground.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
More inspections at Sturgill'S Stucco, INC.
View Sturgill'S Stucco, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340553817.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.