AKRON, OH —
OSHA Inspection: CORPORATE ELECTRIC COMPANY LLC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of CORPORATE ELECTRIC COMPANY LLC in 208 SPRINGSIDE DRIVE, AKRON, OH 44333 (NAICS 238210). OSHA activity number 340554435.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORPORATE ELECTRIC COMPANY LLC
- Site address
- 208 SPRINGSIDE DRIVE
- City
- AKRON
- State
- OH
- ZIP
- 44333
- Mailing
- 378 SOUTH VAN BUREN AVE, BARBERTON, OH 44203
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 26
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.405 A02 II B
- Issued
- May 20, 2015
- Penalty
- Initial $3,500 · Current $1,925 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(B): Runs of open conductors used as temporary wiring branch circuits were located where the conductors would be subject to physical damage, or the conductors were fastened at intervals exceeding 10 feet: On or about April 14, 2015, at a worksite located at 208 Springside Drive, Akron, OH 44333, during construction activities including but not limited to finishing and final electrical installation activities, the employer did not ensure all conductors were properly located to ensure employees were not exposed to physical damage.
Recent events (2)
- — I (S) $1925
- — Z (S) $3500
1926.1052 C01 I
- Issued
- May 20, 2015
- Penalty
- Initial $2,800 · Current $1,540 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: On or about April 14, 2015, at a worksite located at 208 Springside Drive, Akron, OH 44333, during construction activities including but not limited to finishing and final detail activities, the employer did not ensure employees using the existing stairways were provided at least one handrail on stairways having four or more risers. Employees were thereby exposed to falls while ascending and descending the stairways to the second, third and fourth floors to perform work activity.