BURLINGTON, WI —
OSHA Inspection: PERFECT EXTERIORS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PERFECT EXTERIORS INC. in 149-51 JEFFERSON ST., BURLINGTON, WI 53105 (NAICS 238160). OSHA activity number 340556992.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERFECT EXTERIORS INC.
- Site address
- 149-51 JEFFERSON ST.
- City
- BURLINGTON
- State
- WI
- ZIP
- 53105
- Mailing
- W124S6629 HAWTHORNE RD., MUSKEGO, WI 53150
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.20 B02
- Issued
- May 21, 2015
- Abate by
- Jun 17, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: (a) Frequent and regular inspections of the job site were not conducted by a competent person to ensure hazardous conditions were found and corrected.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.503 A01
- Issued
- May 21, 2015
- Abate by
- Jul 9, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) The employer did not ensure that employees exposed to fall hazards had been trained to recognize and minimize the fall hazards associated with their work.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.152 A01
- Issued
- May 21, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.152(a)(1): Containers other than approved metal safety cans or DOT approved containers were used for the handling and use of flammable liquids in quantities of 5 gallons or less: (a) The employer did not ensure that approved safety cans were used for the handling and use of flammable liquids in quantities of 5 gallons or less.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.416 E01
- Issued
- May 21, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: (a) A frayed extension cord was in use to power portable electrical power tools on the job site.
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1926.501 B13
- Issued
- May 21, 2015
- Abate by
- May 21, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Employees conducting roofing activities on a roof with a 10:12 pitch were not protected from falling to the lower level. This exposed employees to a fall hazard of approximately 19.3 feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.1053 B01
- Issued
- May 21, 2015
- Abate by
- May 28, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) The portable ladder being used for access to the roof did not extend at least 3 feet above the upper landing area.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
More inspections at Perfect Exteriors INC.
View Perfect Exteriors INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340556992.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.