Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JAY STRONGWATER, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JAY STRONGWATER, LLC in 107 SALEM STREET, UNION SPRINGS, NY 13160 (NAICS 327112). OSHA activity number 340557644.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JAY Strongwater, LLC — free Get an email when a new federal OSHA severe-injury report for JAY Strongwater, LLC is published. One employer, no account, unsubscribe in one click.
Site address
107 SALEM STREET
City
UNION SPRINGS
State
NY
ZIP
13160
Mailing
107 SALEM STREET, UNION SPRINGS, NY 13160
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327112
Employees
40
Ownership type
A

6 citations on file for this inspection.

1910.176 A

Serious Gravity 1 1 instance 2 exposed
Issued
Jul 2, 2015
Abate by
Aug 7, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.176(a): Aisle(s) and passageway(s) were not kept clear and in good repair with no obstruction across or in aisles that could create a hazard.  a. Within the warehouse, on or about 04/15/15:  Aisle ways were blocked with merchandise including carts and loose boxes.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 2, 2015
Abate by
Jul 18, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.  a.  On the west wall of the warehouse, on or about 04/15/15:  A relocatable power tap, otherwise known as a power strip, was being used to power an industrial floor fan contrary to its listing and labeling instructions.  b.  In the design room, on or about 04/15/15:  A relocatable power tap, otherwise known as a power strip, was being used to power an industrial fume hood contrary to its listing and labeling instructions.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.305 G01 IV A

Serious Gravity 5 2 instances 2 exposed
Issued
Jul 2, 2015
Abate by
Aug 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for fixed wiring of a structure:  a.  In the packing department, on or about 04/15/15:  A circular saw used to build packing crates was powered by an extension cord in lieu of permanent wiring.  b.  In the design room, on or about 04/15/15:  A heat gun used to glue gems onto art pieces was powered by an extension cord in lieu of permanent wiring.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 2, 2015
Abate by
Jul 13, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(g)(1):  Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  a.  Storage area between production area and design, on or about 04/15/15:  Access to a circuit breaker panel was blocked by boxes and a wrought iron decorative screen.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 2, 2015
Abate by
Jul 13, 2015
Penalty
Initial $3,500 · Current $2,625 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  a.  On the south wall of the production area, on or about 04/15/15:  A circuit breaker panel was missing approximately thirteen blanks, thereby exposing its live buss bars.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (S) $2625
  • — Z (S) $3500

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Jul 2, 2015
Abate by
Jul 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  a.  In the area between production and design, on or about 04/15/15:  Access to a mounted fire extinguisher was blocked by boxes and rolling carts.  Abatement certification must be submitted for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JAY Strongwater, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340557644.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.