OSHA Inspection: ASHLIN WOOD CARPENTRY SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ASHLIN WOOD CARPENTRY SERVICES, INC. in 2913 SPOOKY NOOK RD, MANHEIM, PA 17545 (NAICS 236220). OSHA activity number 340559806.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ashlin Wood Carpentry Services, INC. — free Get an email when a new federal OSHA severe-injury report for Ashlin Wood Carpentry Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2913 SPOOKY NOOK RD
City
MANHEIM
State
PA
ZIP
17545
Mailing
604 SPRINGVILLE RD, NEW HOLLAND, PA 17557
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
14
Ownership type
A

2 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 6 exposed
Issued
Jul 8, 2015
Abate by
Aug 3, 2015
Penalty
Initial $1,800 · Current $1,350 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) Northeast 2nd Floor Hotel Wing: A 12/2 NM (non-metallic) cable was wired directly into a cord cap (male plug end) which was drawing power from a duplex electrical outlet.  NM cable is listed and labeled to be used for branch circuits into electrical boxes not into reloadable service plugs, thereby exposing employees to an electrical hazard on or about April 16, 2015.  b) Southeast 2nd Floor Hotel Wing: A 12/2 NM (non-metallic) cable was wired directly into a cord cap (male plug end) which was drawing power from a duplex electrical outlet.  NM cable is listed and labeled to be used for branch circuits into electrical boxes not into reloadable service plugs, thereby exposing employees to an electrical hazard on or about April 16, 2015.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1350
  • — Z (S) $1800

1926.405 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 8, 2015
Abate by
Aug 3, 2015
Penalty
Initial $1,800 · Current $1,350 Reduced
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap:  a)  NORTHEAST HOTEL WING, 3RD FLOOR STAIRWELL LANDING:  On or about April 16, 2015 a 12/2 NM (non-metallic) cable was spliced with a 14/2 minimum duty flat (flexible) cord exposing employees to shock hazards. The 14/2 flat cord splice located 48" above the working surface is not used in a continuous length, does not retain the insulation, outer sheath properties and usage characteristics to be used in this manner.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.