Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. ARMY CORPS OF ENGINEERS, DETROIT DAM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. ARMY CORPS OF ENGINEERS, DETROIT DAM in MP 41, HIGHWAY 22, MILL CITY, OR 97360 (NAICS 221111). OSHA activity number 340560176.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Army Corps of Engineers, Detroit DAM — free Get an email when a new federal OSHA severe-injury report for U.S. Army Corps of Engineers, Detroit DAM is published. One employer, no account, unsubscribe in one click.
Site address
MP 41, HIGHWAY 22
City
MILL CITY
State
OR
ZIP
97360
Mailing
STAR ROUTE BOX 317, MILL CITY, OR 97360
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221111
Employees
20000
Ownership type
D

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 20 exposed
Issued
Oct 9, 2015
Abate by
Nov 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Detroit Dam-  (a) The Dake horizontal band saw's unused portion of the saw blade was unguarded exposing operators to serious injuries.  (b) The spillway gates rotating wheel mechanisms were not guarded to prevent employees from the ingoing nip points, exposing them to serious hazards.
Recent events (1)
  • — Z (S) $0

1910.215 A01

Serious Gravity 5 2 instances 20 exposed
Issued
Oct 9, 2015
Abate by
Nov 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s)  Detroit Dam-  (b) The manufactures guard on the Milwaukie 14" chop saw was missing, exposing employees to serious injuries from the rotating wheel.  (c) The 90 degree angle grinder's abrasive wheel was not guarded to prevent employees from flying debris, exposing them to serious hazards.
Recent events (1)
  • — Z (S) $0

1910.215 A02

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 9, 2015
Abate by
Nov 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections.  Detroit Dam-  (b) The spindle nut on the Milwaukie 14" chop saw was not covered, exposing employees to serious injuries from the rotating nut.
Recent events (1)
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 9, 2015
Abate by
Nov 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting  (a) The horizontal shaft of the drill press, located less than 7 feet from the floor, exposed operator's to serious injuries from the rotating hazard.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 1 1 instance 20 exposed
Issued
Oct 9, 2015
Abate by
Nov 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  Detroit Dam, Elevation 1213-  (a) The Terminal Cabinet- CTCE, had exposed energize terminals of 115 volts, exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $0

View U.S. Army Corps of Engineers, Detroit DAM's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340560176.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.