BRIDGEHAMPTON, NY —
OSHA Inspection: BRIDGEHAMPTON STEEL & WELDING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of BRIDGEHAMPTON STEEL & WELDING, INC. in 260 OCEAN ROAD, BRIDGEHAMPTON, NY 11932 (NAICS 238120). OSHA activity number 340560655.
Where did this inspection happen?
- Establishment
- BRIDGEHAMPTON STEEL & WELDING, INC.
- Site address
- 260 OCEAN ROAD
- City
- BRIDGEHAMPTON
- State
- NY
- ZIP
- 11932
- Mailing
- 27 FOSTER AVENUE P.O. BOX 19, BRIDGEHAMPTON, NY 11932
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.752 B
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.752(b): The steel erection contractor commenced steel erection without receiving written notification that the concrete in the footings, piers and walls or the mortar in the masonry piers and walls had attained, on the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection. (a) 260 Ocean Road, Bridgehampton, NY (Worksite) The employer commenced steel erection activities, in that it installed structural steel posts, ranging in sizes of 5" x 5" x 10'-2" L and 3-1/2" x 3-1/2" x 10'-2" L, and W12 x 96 structural steel beams, approximately 20' L; without receiving written notification that the concrete foundation had attained, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $2250
- — Z (S) $2800
1926.1412 F01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.1412(f)(1): 29 CFR 1926.1412(f)(1): The equipment was not inspected at least every 12 months by a qualified person in accordance with paragraph (d) of this section. (a) Worksite - The employer did not ensure that the National Crane, Model # 900A / Serial # 290557, that was being used to conduct steel erection activities was inspected by a qualified person within the previous 12 months on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $2250
- — Z (S) $2800
1926.1412 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1412(e)(1): 29 CFR 1926.1412(e)(1): The equipment in service was not inspected each month in accordance with paragraph (d) of this section (each shift). (a) Worksite - The employer did not ensure that a competent person completed a monthly inspection of the National Crane, Model # 900A / Serial # 290557. The crane was placed into service to conduct steel erection activities, without having been inspected within the previous month on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1412 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1412(d)(1): A competent person did not begin a visual inspection of the crane prior to each shift the equipment was used or did not complete it before or during that shift: (a) Worksite - The employer did not ensure that a competent person initiated or completed the daily inspection of the National Crane, Model # 900A / Serial # 290557. The crane was placed into service to conduct steel erection activities, without having been inspected prior to; or during the shift on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1417 C01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.1417(c)(1): 29 CFR 1926.1417(c)(1): The procedures applicable to the operation of the equipment, including rated capacities (load charts), recommended operating speeds, special hazard warnings, instructions, and operator's manual, were not readily available in the cab at all times for use by the operator. (a) Worksite - The operator's manual for the National Crane, Model # 900A / Serial # 290557, was not readily available at the worksite when the crane was operated on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $2250
- — Z (S) $2800
1926.1419 A01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2250.00 Reduced
General-duty citation text
29 CFR 1926.1419(a)(1): 29 CFR 1926.1419(a)(1): The employer did not provide a signal person when the point of operation, meaning the load travel or the area near or at load placement, was not in full view of the operator. (a) Worksite - A signal person was not provided when the National Crane, Model # 900A / Serial # 290557, was used to lay out structural steel beams and the area where they were being laid out was not in full view of the crane operator. The area where the structural steel beams were being laid out was located to the crane operator's back and he did not have full view of the area on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $2250
- — Z (S) $2800
More inspections at BRIDGEHAMPTON STEEL & WELDING, INC.
BRIDGEHAMPTON, NY—2019-07-31 00:00:00
BRIDGEHAMPTON STEEL & WELDING, INC
View BRIDGEHAMPTON STEEL & WELDING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
EL PASO, TX—2026-07-15
SURE STEEL
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340560655.