BRIDGEHAMPTON, NY —
OSHA Inspection: MICHAEL DAVIS CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MICHAEL DAVIS CONSTRUCTION, INC. in 260 OCEAN ROAD, BRIDGEHAMPTON, NY 11932 (NAICS 236115). OSHA activity number 340560689.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MICHAEL DAVIS CONSTRUCTION, INC.
- Site address
- 260 OCEAN ROAD
- City
- BRIDGEHAMPTON
- State
- NY
- ZIP
- 11932
- Mailing
- P.O. BOX 452, SAGAPONACK, NY 11962
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.752 A01
- Issued
- Oct 13, 2015
- Abate by
- Oct 27, 2015
- Penalty
- Initial $2,800 · Current $2,200 Reduced
General-duty citation text
29 CFR 1926.752(a)(1): Before authorizing the commencement of steel erection, the controlling contractor did not ensure that the steel erector was provided with written notification that the concrete in the footings, piers and walls and the mortar in the masonry piers and walls had attained, on the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection. (a) 260 Ocean Road, Bridgehampton, NY (Worksite) - The general contractor authorized the steel erection sub-contractor to commence steel erection activities, including, but not limited to the installation of structural steel posts, ranging in sizes of 5 x 5 x 10-2 L and 3-1/2 x 3-1/2 x 10-2 L, and W12 x 96 structural steel beams, approximately 20 L, without ensuring that the concrete foundation had attained, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed by the structural erection on, or about April 15, 2015. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $2200
- — Z (S) $2800
1926.1402 C02
- Issued
- Oct 13, 2015
- Abate by
- Oct 27, 2015
- Penalty
- Initial $2,000 · Current $1,600 Reduced
General-duty citation text
29 CFR 1926.1402(c)(1): 29 CFR 1926.1402(c)(1): The controlling contractor did not inform the user of the equipment and the operator of the location of hazards beneath the equipment set-up area (such as voids, tanks, utilities) when those hazards were identified in documents (such as site drawings, as-built drawings, and soil analyses) that were in the possession of the controlling entity (whether at the site or off-site) or the hazards were otherwise known to that controlling contractor. (a) Worksite - The National Crane, Model # 900A / Serial # 290557, was erected and operated on ground that was previously disturbed. The controlling contractor had prior knowledge that the previous homes foundation was located where the crane was erected and that the ground in that area had recently been backfilled. The controlling contractor did not inform the user and operator of the crane that the ground was previously disturbed on, or about April 15, 2015. Note: The employer is required to submit abatement documentation for this violation, in accordance with 29 CFR 1903.19.
Recent events (2)
- — I (S) $1600
- — Z (S) $2000
More inspections at Michael Davis Construction, INC.
View Michael Davis Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340560689.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.