OSHA Inspection: BRACKENRIDGE CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BRACKENRIDGE CONSTRUCTION in 295 MALL ROAD, SAINT CLAIRSVILLE, OH 43950 (NAICS 236220). OSHA activity number 340561323.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brackenridge Construction — free Get an email when a new federal OSHA severe-injury report for Brackenridge Construction is published. One employer, no account, unsubscribe in one click.
Site address
295 MALL ROAD
City
SAINT CLAIRSVILLE
State
OH
ZIP
43950
Mailing
P.O. BOX 220, BRACKENRIDGE, PA 15014
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
30
Ownership type
A

8 citations on file for this inspection.

1926.403 B02

Other-than-serious 2 instances 5 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.403(b)(2): Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.    a. Next to the "desk" a relocatable power tap was being used on a construction site, in violation of the UL listing and labeling, thereby exposing employees to an electrical hazard.    b. Next to the "desk" a relocatable power tap was daisy chained with extension cords, the power tap was plugged into an extension cord and a second extension cord was run from the power tap to where contractors were using it for portable tools, thereby exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $3850
  • — Z (S) $3850

1926.404 F06

Other-than-serious 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.    a. The flexible cord powering the pipe threader was missing the grounding pin, thereby exposing employees to contact with electrical hazard.
Recent events (2)
  • — I (O) $3850
  • — Z (S) $3850

1926.405 B01

Serious Gravity 5 3 instances 15 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.    a. Temporary electrical panel box L, had four unused openings on the top of the box, thereby exposing employees to contact with live electrical current.    b. At the top of the temporary electrical panel box L, the main electrical going into the panel and 3 romex cords leaving the top of the panel box were not protected with a fitting or bushing from abrasion, thereby exposing employees to contact with live electrical current.    c. The receptacle box mounted near panel box L had an unused opening on the right side of the box, thereby exposing employees to contact with live electrical current.
Recent events (2)
  • — I (S) $3850
  • — Z (S) $3850

1926.405 D

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $3,850 · Current $0 Reduced
29 CFR 1926.405(d): Switchboards and panelboards. Switchboards that have any exposed live parts shall be located in permanently dry locations and accessible only to qualified persons. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons. Exposed blades of knife switches shall be dead when open.    a. The switchboard inside the electrical cabinet H was not dead front, thereby exposing employees to live exposed parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3850

1926.501 B04 II

Other-than-serious 1 instance 15 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $2,310 · Current $2,310
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.    Near the east wall of the building there was an exposed floor hole that measured 4 inches deep and 23 inches wide and 1 foot long, thereby exposing employees to a tripping hazard.
Recent events (2)
  • — I (O) $2310
  • — Z (S) $2310

1926.502 I03

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(3): All covers shall be secured when installed so as to prevent accidental displacement by the wind, equipment, or employees.  a. The floor hole cover on the East side of the building was not secured to prevent accidental displacement, thereby exposing employees to a tripping hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 I04

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(i)(4): All covers shall be color coded or they shall be marked with the word "HOLE" or "COVER" to provide warning of the hazard. Note: This provision does not apply to cast iron manhole covers or steel grates used on streets or roadways.  a. The floor hole cover on the east side of the building was not marked with the word hole or cover, thereby exposing employees to a tripping hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Deleted Repeat Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 12, 2015
Penalty
Initial $10,780 · Current $0 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.   a. An employee was observed standing on the piece of steel where exposed to a 12-15 foot fall hazard.   Brackenridge Construction was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 986948, citation number 1, item number 1 and was affirmed as a final order on 11/17/2014, with respect to a workplace located at 101 Independence Mall Way, Kingston, MA 02364.
Recent events (2)
  • — I (R) $0
  • — Z (R) $10780

View Brackenridge Construction's full OSHA safety record →