Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUEST DIAGNOSTICS INCORPORATED

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUEST DIAGNOSTICS INCORPORATED in 6 RYE RIDGE PLAZA, RYE BROOK, NY 10573 (NAICS 621511). OSHA activity number 340562735.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quest Diagnostics Incorporated — free Get an email when a new federal OSHA severe-injury report for Quest Diagnostics Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
6 RYE RIDGE PLAZA
City
RYE BROOK
State
NY
ZIP
10573
Mailing
ONE MALCOLM AVENUE, TETERBORO, NJ 07608
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
621511
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.1030 C01 IV B

Other-than-serious 1 instance 2 exposed
Issued
Oct 16, 2015
Abate by
Jan 15, 2016
Penalty
Initial $4,250 · Current $0 Reduced
29 CFR 1910.1030(c)(1)(iv)(B): The review and update of the exposure control plan did not document annually consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure:    a) Entire Facility:  Where employees spin in centrifuges Becton Dickenson (BD) glass blood collection tubes containing 3.2% sodium citrate solution or Covidien Monoject Trace Element glass blood collection tubes, containing EDTA (Na2); the employer's Exposure Control Plan did not document consideration and implementation of safer (plastic) blood collection tubes instead; on or about 4/16/15.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4250

1910.1030 D02 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Oct 16, 2015
Abate by
Nov 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1030(d)(2)(i): Engineering and work practice controls were not used to eliminate or minimize employees exposure:  a) Entire Facility:  Where employees spin in centrifuges Becton Dickenson (BD) glass blood collection tubes containing 3.2% sodium citrate solution or Covidien Monoject Trace Element glass blood collection tubes, containing EDTA (Na2); the employer did not implement use of engineering controls such as safer (plastic) tubes; on or about 4/16/15.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Quest Diagnostics Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340562735.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.