CHARLESTON, WV ·
OSHA Inspection: C C SPIKE COPLEY GARAGE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of C C SPIKE COPLEY GARAGE, INC. in 1009 CENTRAL AVENUE, CHARLESTON, WV 25302 (NAICS 488410). OSHA activity number 340563063.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C C SPIKE COPLEY GARAGE, INC.
- Site address
- 1009 CENTRAL AVENUE
- City
- CHARLESTON
- State
- WV
- ZIP
- 25302
- Mailing
- 1009 CENTRAL AVENUE, CHARLESTON, WV 25302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488410
- Employees
- 13
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.147 C01
- Issued
- May 14, 2015
- Abate by
- Jul 1, 2015
- Penalty
- Initial $2,400 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a.) C C Spike Copley Garage, Inc.: On or about 4/16/15, the employer had not developed an energy control program for employees performing service and maintenance on equipment with stored energy such as when working on motor vehicles. ABATEMENT CERTIFICIATION IS REQURIED.
Recent events (2)
- · I (S) $1200
- · Z (S) $2400
1910.215 A02
- Issued
- May 14, 2015
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a.) C C Spike Copley Garage, Inc., Shop Area: On or about 4/16/15, the Dewalt 6" bench grinder was not equipped with a guard over the spindle end.
Recent events (2)
- · I (S) $680
- · Z (S) $1360
1910.215 B09
- Issued
- May 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a.) C C Spike Copley Garage, Inc., Shop Area: On or about 4/16/15, the Dewalt 6" bench grinder used by employees was not equipped with a tongue guard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.215 A04
- Issued
- May 14, 2015
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a.) C C Spike Copley Garage, Inc., Shop Area: On or about 4/16/15, the Dewalt 6" bench grinder was not equipped with a work rest while employees used the abrasive wheel.
Recent events (2)
- · I (S) $680
- · Z (S) $1360
1910.253 B02 II
- Issued
- May 14, 2015
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a.) C C Spike Copley Garage, Inc., Shop Area: On or about 4/16/15, four oxygen and fuel gas cylinders were stored in the middle of the shop floor where they could be knocked over or damaged.
Recent events (2)
- · I (S) $680
- · Z (S) $1360
1910.253 B04 III
- Issued
- May 14, 2015
- Penalty
- Initial $1,360 · Current $680 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour. a.) C C Spike Copley Garage, Inc., Shop Area: On or about 4/16/15, compressed gas cylinders of oxygen and acetylene were stored together.
Recent events (2)
- · I (S) $680
- · Z (S) $1360
1904.32 A02
- Issued
- May 14, 2015
- Abate by
- Jul 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.32(a)(2): The employer did not create an annual summary of injuries and illnesses recorded on the OSHA 300 log: a.) C C Spike Copley Garage, Inc.: On or about 4/16/15, the employer did not create an annual summary of injury and illnesses that were recorded on the OSHA 300 log. ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 488410)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340563063.