Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C C SPIKE COPLEY GARAGE, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C C SPIKE COPLEY GARAGE, INC. in 1009 CENTRAL AVENUE, CHARLESTON, WV 25302 (NAICS 488410). OSHA activity number 340563063.

Watch C C Spike Copley Garage, INC. — free Get an email when a new federal OSHA severe-injury report for C C Spike Copley Garage, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1009 CENTRAL AVENUE
City
CHARLESTON
State
WV
ZIP
25302
Mailing
1009 CENTRAL AVENUE, CHARLESTON, WV 25302
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488410
Employees
13
Ownership type
A

7 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2400.00 · Current $1200.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a.)  C C Spike Copley Garage, Inc.:  On or about 4/16/15, the employer had not developed an energy control program for employees performing service and maintenance on equipment with stored energy such as when working on motor vehicles.      ABATEMENT CERTIFICIATION IS REQURIED.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2400

1910.215 A02

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:    a.)  C C Spike Copley Garage, Inc., Shop Area:  On or about 4/16/15, the Dewalt 6" bench grinder was not equipped with a guard over the spindle end.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.215 B09

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a.)  C C Spike Copley Garage, Inc., Shop Area:  On or about 4/16/15, the Dewalt 6" bench grinder used by employees was not equipped with a tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:    a.)  C C Spike Copley Garage, Inc., Shop Area:  On or about 4/16/15, the Dewalt 6" bench grinder was not equipped with a work rest while employees used the abrasive wheel.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.253 B02 II

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    a.)  C C Spike Copley Garage, Inc., Shop Area:  On or about 4/16/15, four oxygen and fuel gas cylinders were stored in the middle of the shop floor where they could be knocked over or damaged.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1910.253 B04 III

Serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $1360.00 · Current $680.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour.    a.)  C C Spike Copley Garage, Inc., Shop Area:  On or about 4/16/15, compressed gas cylinders of oxygen and acetylene were stored together.
Recent events (2)
  • — I (S) $680
  • — Z (S) $1360

1904.32 A02

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.32(a)(2): The employer did not create an annual summary of injuries and illnesses recorded on the OSHA 300 log:  a.)  C C Spike Copley Garage, Inc.: On or about 4/16/15, the employer did not create an annual summary of injury and illnesses that were recorded on the OSHA 300 log.  ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

UNKNOWN

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340563063.