Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSALL ROOFING & SHEET METAL, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JOSALL ROOFING & SHEET METAL, INC. in OWCA, 4170 ROUTE 31, CLAY, NY 13041 (NAICS 238160). OSHA activity number 340564558.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Josall Roofing & Sheet Metal, INC. — free Get an email when a new federal OSHA severe-injury report for Josall Roofing & Sheet Metal, INC. is published. One employer, no account, unsubscribe in one click.
Site address
OWCA, 4170 ROUTE 31
City
CLAY
State
NY
ZIP
13041
Mailing
PO BOX 158, EASTWOOD STREET, SYRACUSE, NY 13206
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.502 B03

Other-than-serious 1 instance 7 exposed
Issued
May 22, 2015
Abate by
Jun 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:  a)  At the jobsite, on the roof, on or about 4/14/15:  Workers were performing roofing work on an irregularly shaped roof where a cable guardrail system was installed, and where that cable system was incorrectly installed and not able to assure the 200 pound minimum force requirement.    Abatement certification must be submitted for this item.
Recent events (1)
  • — Z (O) $0

1926.503 A02 II

Other-than-serious 1 instance 7 exposed
Issued
May 22, 2015
Abate by
Jun 27, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:  a)  At the jobsite, on the roof, on or about 4/14/15:  Workers were performing roofing work on an irregularly shaped roof where a cable guardrail system was installed, and where that cable system was incorrectly installed and not able to assure the 200 pound minimum force requirement nor were workers trained to recognize the faulty installation.     Abatement certification must be submitted for this item.