WASHINGTON, DC —
OSHA Inspection: ENCOMPASS BUILDERS AND DEVELOPERS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ENCOMPASS BUILDERS AND DEVELOPERS LLC in 4508 BLAGDEN AVE NW, WASHINGTON, DC 20011 (NAICS 238160). OSHA activity number 340565233.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENCOMPASS BUILDERS AND DEVELOPERS LLC
- Site address
- 4508 BLAGDEN AVE NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20011
- Mailing
- 2633 15TH STREET NW SUITE 5, WASHINGTON, DC 20009
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Jun 26, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On April 17, 2015 and at times prior thereto; roof area; employees were installing shingles on a 10:12 and 4:12 pitch roof without fall protection to protect them from falling an estimated 25-35 feet to ground level.
Recent events (1)
- — Z (S) $2800
1926.1053 B01
- Issued
- Jun 26, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On April 17, 2015 and at times prior thereto; front of building/SE side; employees were exposed to a fall hazard of 25 feet to ground level while using the extension ladder that was extended 18 inches above the working platform.
Recent events (1)
- — Z (S) $2000
More inspections at Encompass Builders and Developers LLC
View Encompass Builders and Developers LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340565233.