Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACTCO TOOL & MFG. CO.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ACTCO TOOL & MFG. CO. in 14421 BALDWIN ST. EXT., MEADVILLE, PA 16335 (NAICS 333514). OSHA activity number 340566108.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Actco Tool & MFG. CO. — free Get an email when a new federal OSHA severe-injury report for Actco Tool & MFG. CO. is published. One employer, no account, unsubscribe in one click.
Site address
14421 BALDWIN ST. EXT.
City
MEADVILLE
State
PA
ZIP
16335
Mailing
P.O. BOX 675, MEADVILLE, PA 16335
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333514
Employees
28
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2015
Abate by
Nov 4, 2015
Penalty
Initial $2,800 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:  a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 and times prior thereto, employees were exposed to fire and fall hazards in the heat treat furnace room which did not have emergency lighting available to mark the exit route. The room was not configured in a way that windows could provide supplemental illumination during an emergency or power outage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2800

1910.37 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 17, 2015
Abate by
Oct 14, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":     a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 the room with the heat treat furnace did not have an exit sign to mark the door to leave through in the event of an emergency.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.147 C04 II

Serious Gravity 5 1 instance 30 exposed
Issued
Sep 17, 2015
Abate by
Nov 4, 2015
Penalty
Initial $3,500 · Current $1,800 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 and times prior thereto, employees periodically performed servicing and maintenance on various machines including, but not limited to, saws, CNCs and various grinders. The procedures did not include specific information regarding the scope, purpose, rules and techniques to be utilized for the control of hazardous energy; a specific statement of the intended use of the procedures; specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; specific procedural steps for testing machines and equipment to verify the de-energization; specific requirements for notification of affected employees; specific procedures for re-energization of the machines; specific requirements for inspections of work area prior to reenergizing equipment; and specific requirements for notification of employees prior to reenergizing equipment.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3500

1910.147 C06 II

Serious Gravity 5 1 instance 30 exposed
Issued
Sep 17, 2015
Abate by
Nov 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 and times prior thereto: Authorized employees are permitted to periodically perform servicing and maintenance on various machines including but not limited to, cnc, lathes, saws, milling, edm and wedm equipment. The employer did not certify that periodic inspections of the lockout/tagout program and procedures occurred.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 17, 2015
Abate by
Oct 14, 2015
Penalty
Initial $3,500 · Current $1,800 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 a Roll-In Bandsaw did not having guarding to protect the unused portion of the saw blade during cutting operations.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3500

1910.215 B09

Serious Gravity 5 2 instances 15 exposed
Issued
Sep 17, 2015
Abate by
Oct 14, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:       a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 a Boldt Machinery and Tools grinder in the lathe department was missing a tongue guard on the left and the right abrasive wheels of the pedestal grinder.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.215 A04

Deleted Serious Gravity 5 2 instances 15 exposed
Issued
Sep 17, 2015
Abate by
Oct 14, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 a grinder in the grind department without an identifiable manufacturer, model or serial number did not have a work rest for the abrasive grinding wheels on the right or the left side.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 15 exposed
Issued
Sep 17, 2015
Abate by
Oct 14, 2015
Penalty
Initial $3,500 · Current $1,800 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:    a) Actco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 a welding cart that was holding both oxygen and fuel gas had been stored together for several months in the maintenance area. The cylinders were not separated from each other by 20 feet.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3500

1910.303 B02

Serious Gravity 5 6 instances 30 exposed
Issued
Sep 17, 2015
Abate by
Oct 14, 2015
Penalty
Initial $3,500 · Current $1,800 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Atco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 in the grind area, the Delta Rockwell Sander Grinder was plugged into an outlet with a knockout style receptacle box that was not mounted/secured to the wall. The knockout style receptacle box was being used as permanent extension cord.      b) Atco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 in the EDM between the Elite Pulistron P00CP and the Elite Pulsitron TRM-21, a Futaba Pulscale was plugged into an outlet with knockout style receptacle box that was not mounted/secured to the wall. The knockout style receptacle box was being used as permanent extension cord.      c) Atco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 in the lathe area, a position readout for the Mitutoyo UDR 220 was plugged into an outlet with knockout style receptacle box that was not mounted/secured. The knockout style receptacle box is designed to be secured to keep it in place.      d) Atco Tool & Manufacturing Co. / 1421 Baldwin St, Meadville PA: On or about April 17, 2015 by the exit door in the saw room, a knockout style receptacle box was setting on a covered trash can and was plugged into an outlet on the wall. The knockout style receptacle box was being used as an extension cord.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3500

View Actco Tool & MFG. CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340566108.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.