ELY, NV —
OSHA Inspection: USDA FOREST SERVICE, ELY RANGER DISTRICT, FIRE CASHE WAREHOUSE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of USDA FOREST SERVICE, ELY RANGER DISTRICT, FIRE CASHE WAREHOUSE in 825 AVENUE E, ELY, NV 89301 (NAICS 924120). OSHA activity number 340566652.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 825 AVENUE E
- City
- ELY
- State
- NV
- ZIP
- 89301
- Mailing
- 825 AVENUE E, ELY, NV 89301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 924120
- Employees
- 20
- Ownership type
- D
Citations
7 citations on file for this inspection.
1910.22 D01
- Issued
- Jul 30, 2015
- Abate by
- Nov 1, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purpose, the load approved by the building official was not appropriately marked and posted: (a) Fire CASHE Warehouse: On or about April 14, 2015 and times prior, employees were exposed a fall to the concrete below or collapse of overloaded floor storage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Jul 30, 2015
- Abate by
- Aug 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) Fire CASHE Warehouse: On or about April 14, 2015 and times prior, employees were exposed to flying parts from Six Inch Dayton Bench Grinder in that the tongue guard was missing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 F02
- Issued
- Jul 30, 2015
- Abate by
- Aug 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Basement: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire from all circuit breakers of electrical power panel were not labeled.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Jul 30, 2015
- Abate by
- Aug 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for fixed wiring of a structure: (a) Fire CASHE Warehouse: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord to provide power to charge the batteries of the MORBARK Beever M12R Brush Chipper. (b) Wellness Room: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord to provide power to Television and Stereo equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV C
- Issued
- Jul 30, 2015
- Abate by
- Aug 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were used where run through doorways, windows, or similar openings: (a) Fire CASHE Warehouse: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord to provide power to charge the batteries of the MORBARK Beever M12R Brush Chipper.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV D
- Issued
- Jul 30, 2015
- Abate by
- Aug 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces: (a) Fire CASHE Warehouse: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord to provide power to charge the batteries of the MORBARK Beever M12R Brush Chipper. (b) Wellness Room: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire by using a flexible cord to provide power to Television and Stereo equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Jul 30, 2015
- Abate by
- Aug 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Fire CASHE Warehouse: On or about April 14, 2015 and times prior, employees are exposed to electric shock/fire by using a Six Inch Dayton Bench Grinder with a 120 volt flexible power cord with the outer sheath pulled away from the plug attachment and the base of the grinder.
Recent events (2)
- — I (S) $0
- — Z (S) $0