CONROE, TX —
OSHA Inspection: INOCENCIO VIERA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INOCENCIO VIERA in 12279 LITTLE BLUE HERRON, CONROE, TX 77304 (NAICS 238140). OSHA activity number 340576560.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INOCENCIO VIERA
- Site address
- 12279 LITTLE BLUE HERRON
- City
- CONROE
- State
- TX
- ZIP
- 77304
- Mailing
- 18557 HUCKLEBERRY LANE, PORTER, TX 77365
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Apr 29, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. The employer does not ensure that each platform on all working levels of scaffolds was fully planked or decked between the front uprights and the guardrail supports. This violation was observed on or about April 21, 2015 when employees were exposed to an approximate six foot fall hazard while doing masonry work form the first level of a framed metal tubular scaffold without it being fully planked. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all working levels of scaffolds are fully planked or decked between the front uprights and the guardrail supports.
Recent events (1)
- — Z (S) $2000
1926.451 E01
- Issued
- Apr 29, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access. The employer does not ensure that employees have a ladder, stairway, or ramp to access a scaffold. This violation occurred on or about April 21, 2015, when employees were exposed to a fall hazard while doing masonry work from the first level of a scaffold without adequate access. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees have proper access to the scaffold platform.
Recent events (1)
- — Z (S) $1200
1926.501 B13
- Issued
- Apr 29, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). The employer does not protect employees from falling when working 6 feet or more above lower levels. This violation was observed on or about April 21, 2015, at the residential construction site where employees were exposed to an approximate nine foot fall hazard when performing masonry activities on a roof without a fall protection system. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that employees engaged in residential construction activities 6 feet or more above lower levels are protected from falling.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340576560.