HURRICANE, WV —
OSHA Inspection: PYRAMID PALLETS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PYRAMID PALLETS in 2419 US ROUTE 60, HURRICANE, WV 25526 (NAICS 321920). OSHA activity number 340576719.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PYRAMID PALLETS
- Site address
- 2419 US ROUTE 60
- City
- HURRICANE
- State
- WV
- ZIP
- 25526
- Mailing
- P.O. BOX 297, HURRICANE, WV 25526
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.133 A03
- Issued
- Jul 22, 2015
- Abate by
- Aug 17, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee, who wore prescription lenses while engaged in operations that involved eye hazards, used protection that incorporated the prescription in its design, or wore eye protection over the prescription glasses or protective lenses with side shields: (a) Pallet Building Area: Two employees wore prescription glasses while operating a circular saw, reciprocating saw and chop saw to cut wood used to build and recycle wooden pallets. The employees' prescription glasses were not impact resistant or equipped with side shields, as observed on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $1200
1910.178 L01 I
- Issued
- Jul 22, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) Facility Wide: Employees operate a Toyota forklift (serial #12781, model #8FGU15) to move pallets around the facility. The employer has not ensured that employees received training and were evaluated on the operation of the forklift prior to forklift use, as determined on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $1200
1910.303 B01 II
- Issued
- Jul 22, 2015
- Abate by
- Aug 10, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the mechanical strength and durability were not maintained: (a) Pallet Building Station: An employee used a Skil Circular Saw that was provided power from an extension cord that was damaged in three places exposing the employee to the energized insulated conductors, as observed on April 22, 2015. (b) Pallet Building Station: An employee used a DeWalt reciprocating saw that was equipped with a damaged power cord exposing the employee to the energized insulated conductors, as observed on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $1200
1910.303 G02 I
- Issued
- Jul 22, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): (a) Front of Shop: A 240 volt, 100 amp breaker box containing 3 breakers was not equipped with a cover which exposed employees to live energized parts, as observed on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $2000
1910.305 D02
- Issued
- Jul 22, 2015
- Abate by
- Aug 3, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and/or were not dead front: (a) Front of Shop: A 240 volt, 100 amp breaker box containing 3 breakers was not installed in a cabinet and was not dead front which exposed employees to live energized parts, as observed on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $0
1910.1200 E01
- Issued
- Jul 22, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Pyramid Pallet: Employees use saws to dismantle and rebuild pallets which produce combustible wood dust. The employer has not developed or implemented a written hazard communication program for employees exposed to combustible wood dust, as determined on April 22, 2015. ABATEMENT NOTE: A written program shall include a description of how the criteria for the following will be met: 1. Labeling and other forms of warnings; 2. Safety Data Sheets; 3. Employee information and training. Additionally, a list of hazardous chemicals known to be present in the workplace must be compiled. Methods used to inform employees of the hazards associated with non-routine tasks and the informing of contractors of workplace hazards, including a description of the labeling system used in the facility and the availability of safety data sheets must also be addressed. The written program must be made available upon request. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $1200
1910.1200 H01
- Issued
- Jul 22, 2015
- Abate by
- Aug 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Pyramid Pallet: Employees use saws to dismantle and rebuild pallets which produce combustible wood dust. The employer has not provided employees with information and training on the hazards of the combustible wood dust, as determined on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (S) $0
1910.37 B02
- Issued
- Jul 22, 2015
- Abate by
- Aug 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly marked by a sign reading "Exit": (a) Workshop: The designated exit door inside the workshop was not marked with a sign reading "Exit", as determined on April 22, 2015. Abatement Certification Required for this Item.
Recent events (1)
- — Z (O) $0
More inspections at Pyramid Pallets
View Pyramid Pallets's full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in WV
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340576719.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.