WALTHAM, MA —
OSHA Inspection: COMPRINT, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of COMPRINT, INC. in 216 R. NEWTON STREET, WALTHAM, MA 02454 (NAICS 313310). OSHA activity number 340577022.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPRINT, INC.
- Site address
- 216 R. NEWTON STREET
- City
- WALTHAM
- State
- MA
- ZIP
- 02454
- Mailing
- 216 R. NEWTON STREET, WALTHAM, MA 02453
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 313310
- Employees
- 23
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.36 G04
- Issued
- Oct 7, 2015
- Abate by
- Nov 25, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.36(g)(4): Objects that projected into the exit route reduced the width of the exit route to less than the 28 inches minimum width requirements for exit routes: Location: Dryer Department On or about 5/13/15, employees were exposed to fire and entrapment hazards as a result of a movable wooden table and boxes of t-shirts restricting an exit access for employees that work in this area.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.147 C01
- Issued
- Oct 7, 2015
- Abate by
- Nov 25, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Location: Dryer Department On or about 4/22/15, the employer did not establish an energy control program consisting of energy control procedures, employee training, and periodic inspections including but not limited to the employees who clean and service the following but not limited to machines; 1. Sprint 2000, 60 series main gas dryer, 2. Electric Dryer #1, 3. Electric Dryer #2.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1910.219 D01
- Issued
- Oct 7, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Location: Dryer Department On or about 4/22/15, the employer did not guard the belt and pulley of the Sprint 2000 dryer to protect employees from in-going nip-points.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.242 B
- Issued
- Oct 7, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i: Location: Receiving Area On or about 4/22/2015, the employer did not reduce the compressed air nozzles used for cleaning to less than 30 p.s.i. as required.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.303 G01
- Issued
- Oct 7, 2015
- Abate by
- Nov 25, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Location: Receiving Area On or about 4/22/15 and 5/13/15, the employer's electrical cabinet access was not readily accessible to employees who reset breakers.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.305 G01 IV
- Issued
- Oct 7, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a): Location: Ink Department On or about 4/22/15, an extension cord was being used in lieu of fixed wiring to power a relocatable power tap that was being used to power a fan and a scale. Location: Screen Department On or about 5/13/15, an extension cord was being used in lieu of fixed wiring to power a fan. Location: Warehouse On or about 5/13/15, an extension cord was being used in lieu of fixed wiring to power a fan.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1910.38 B
- Issued
- Oct 7, 2015
- Abate by
- Nov 25, 2015
- Penalty
- Initial $400 · Current $200 Reduced
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: Location: Facility On or about 4/22/15, the employer did not have a written emergency action plan at the workplace and was not available for employees to review.
Recent events (2)
- — I (O) $200
- — Z (O) $400
More inspections at Comprint, INC.
View Comprint, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 313310)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340577022.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.