SAINT JOSEPH, MO —
OSHA Inspection: REARDON MACHINE CO. INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REARDON MACHINE CO. INC. in 5015 SE HWY 169, SAINT JOSEPH, MO 64507 (NAICS 332710). OSHA activity number 340580422.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REARDON MACHINE CO. INC.
- Site address
- 5015 SE HWY 169
- City
- SAINT JOSEPH
- State
- MO
- ZIP
- 64507
- Mailing
- 5015 SE HWY 169, SAINT JOSEPH, MO 64507
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- No inspection (D)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 22
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B02
- Issued
- Jun 15, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) In the southwest corner of the machine shop a vertical drill press was plugged into a power strip intended only for computer peripherals. ABATEMENT CERTIFICATION IS NOT REQUIRED FOR THIS ITEM.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
1910.305 B01 I
- Issued
- Jun 15, 2015
- Penalty
- Initial $1,200 · Current $840 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: (a) The bushing on the power conductor entering the vertical drill press was loose and subjected the conductors to damage. ABATEMENT CERTIFICATION IS NOT REQUIRED FOR THIS ITEM.
Recent events (2)
- — I (S) $840
- — Z (S) $1200
More inspections at Reardon Machine CO. INC.
View Reardon Machine CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340580422.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.