DOUGLASVILLE, GA —
OSHA Inspection: ASPHALT REFINING & TECHNOLOGY COMPANY, LLC
Federal Agency inspection · Health discipline
At a glance
On , OSHA opened a federal Agency health inspection of ASPHALT REFINING & TECHNOLOGY COMPANY, LLC in 7982 HUEY ROAD, DOUGLASVILLE, GA 30134 (NAICS 324122). OSHA activity number 340584929.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASPHALT REFINING & TECHNOLOGY COMPANY, LLC
- Site address
- 7982 HUEY ROAD
- City
- DOUGLASVILLE
- State
- GA
- ZIP
- 30134
- Mailing
- 7982 HUEY ROAD, DOUGLASVILLE, GA 30134
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324122
- Employees
- 27
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 A02
- Issued
- Oct 21, 2015
- Abate by
- Nov 9, 2015
- Penalty
- Initial $5,950 · Current $5,950
General-duty citation text
29 CFR 1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employees: a) PMA Plant - The employer failed to provide self-contained breathing apparatus, ( SCBA) to employees working on top of the Blend Tanks 1 and 2 when adding bags of Butaphalt -720 cross-linker to liquid asphalt manually. Employees were exposed to unknown concentration of hydrogen sulfide.
Recent events (2)
- — I (S) $5950
- — Z (S) $5950
1910.1000 B02
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(b)(2): Employee(s) were exposed to an airborne concentration of Hydrogen Sulfide listed in Table Z-2 in excess of the ceiling concentration of 3.8 microgram/ml for thiosulfate: (Thiosulfate is one the major metabolites of sulfide that is commonly in blood, therefore is the compound tested in Hydrogen Sulfide exposure) A) PMA Plant - An employee was exposed to hydrogen sulfide in excess of the ceiling concentration of 3.8 microgram/ml for thiosulfate when working on top the Blend Tanks 1&2 and dropping bags of Butaphalt-720 cross-linker with ingredient of hydrogen sulfide into the Blend Tanks 1&2. Elevated levels of thiosulfate (3.8 microgram/ml) were found.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 E
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): a) PMA Plant - The employer failed to ensure and to provide the feasible administrative and engineering controls for hydrogen sulfide gas present in the vapor of the polymer modified asphalt for employees adding Butaphalt -720 cross-linker to the liquid asphalt manually
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G08
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $4,200 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s) a) PMA Plant - The employer failed to provide and maintain copies of safety data sheets for hazardous chemicals such as, but not limited to, Butaphalt -720 cross-linker, which contains sulfur and phenolic resin. b) Roofing Dock area - The employer failed to provide temporary workers safety data sheets for hazardous chemicals such as, but not limited to: Hydrated Lime (calcium hydroxide) and liquid asphalts (hydrogen sulfide, sulfur oxide).
Recent events (2)
- — I (O) $0
- — Z (S) $4200
1910.1200 H01
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Throughout facility - The employer failed to provide the information and training to employees working with hazardous chemicals such as, but not limited to: styrene, calcium hydroxide and liquid asphalts, hydrogen sulfide, phenol and formaldehyde.
Recent events (2)
- — I (S) $2500
- — Z (S) $4900
1910.134 C02 I
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Throughout facility - The employer failed to provide employees with the information contained in Appendix D of Respiratory Protection Program when employees were permitted to use the N-95 particulate dust mask voluntarily, exposing them to respiratory tract irritations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Oct 21, 2015
- Abate by
- Nov 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate material safety data sheet: A) Throughout facility - Employer failed to provide a complete list of the hazardous chemicals known to be present at the in the PMA Plant and Roofing Dock. The list of chemicals did not include chemicals such as Performance Graded Binder (hydrogen sulfide and sulfur oxide), KOSYN KTR SBS Polymers (styrene), Hydrated Lime (calcium hydroxide) and Propane.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Asphalt Refining & Technology Company, LLC
View Asphalt Refining & Technology Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 324122)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340584929.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.