OSHA Inspection: YORK RESTORATION

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of YORK RESTORATION in 140 WEST END AVE, NEW YORK, NY 10023 (NAICS 238140). OSHA activity number 340587419.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch York Restoration — free Get an email when a new federal OSHA severe-injury report for York Restoration is published. One employer, no account, unsubscribe in one click.
Establishment
YORK RESTORATION
Site address
140 WEST END AVE
City
NEW YORK
State
NY
ZIP
10023
Mailing
34-02 LAUREL HILL BLVD, MASPETH NY 11378, MASPETH, NY 11378
Inspection type
Special Programs (K)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
20
Ownership type
A

4 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program of frequent and regular inspections made by competent persons at the jobsite:      a)  The employer did not have a program to conduct frequent and regular inspections at the site.  Employees were exposed to fall hazard, electric shock hazard when doing exterior masonry repairs on the 30 story apartment building.       Location: 140 West End Ave, New York, N.Y.      On or about 3/31/2015               NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — F (S) $1400
  • — C (S) $2000
  • — Z (S) $2000

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 29, 2015
Penalty
Initial $2,800 · Current $1,950 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which is 6 feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:      a) Employees were exposed to fall hazard doing masonry repair work on the 17th floor balcony.  The employer removed all of the balcony railings as part of the masonry repairs to the 30 story apartment building.       Location: 140 West End Ave, New York, N.Y.      On or about 3/31/2015               NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — R (S) $1950
  • — C (S) $2800
  • — Z (S) $2800

1926.404 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters (GFCI) or an assured grounding program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites from electric shock hazard when using electric tools and equipment:      a)  Employees were exposed to electric shock hazard using electric tools and equipment without ground fault circuit protection (GFI).  Masonry tools were connected to the blue extension cord which was plugged in to an power outlet on the scaffold. No GFI was being used.       Location: 140 West End Ave, New York, N.Y.      On or about 3/31/2015               NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — R (S) $1400
  • — C (S) $2000
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 29, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits and equipment was not permanent and continuous:      a) Employees were exposed to electric shock hazard using ungrounded tools and equipment on a 2 point suspended scaffold.  Masonry tools were connected to the blue extension cord which was plugged in to an ungrounded power outlet on the scaffold.      Location: 140 West End Ave, New York, N.Y.      On or about 3/31/2015               NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
  • — R (S) $0
  • — C (S) $2000
  • — Z (S) $2000

View York Restoration's full OSHA safety record →