Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOUTHERN ERECTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOUTHERN ERECTORS, INC. in 1750 INLAND ROAD, ORANGE, TX 77632 (NAICS 238120). OSHA activity number 340587880.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southern Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Southern Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1750 INLAND ROAD
City
ORANGE
State
TX
ZIP
77632
Mailing
6540 WEST 9 MILE RD, PENSACOLA, FL 32526
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
40
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 27, 2015
Abate by
Sep 23, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:        At the #2 Recovery Boiler Precipitator, NWL model #101659; the employer did not ensure that employees were trained in recognizing the applicable hazardous energy sources or the function of the energy control program, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $7000
  • — Z (S) $7000

1910.147 D05 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 27, 2015
Abate by
Sep 23, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(d)(5)(i):  Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices.        At the #2 Recovery Boiler Precipitator, NWL model #101659; the employer did not ensure that employees relieved stored energy and rendered safe, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $7000
  • — Z (S) $7000

1910.147 D06

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 27, 2015
Abate by
Sep 23, 2015
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:        At the #2 Recovery Boiler Precipitator, NWL model #101659; the employer did not verify the isolation and deenergization prior to starting working on the insulators, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

View Southern Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340587880.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.