ORANGE, TX —
OSHA Inspection: SOUTHERN ERECTORS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOUTHERN ERECTORS, INC. in 1750 INLAND ROAD, ORANGE, TX 77632 (NAICS 238120). OSHA activity number 340587880.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHERN ERECTORS, INC.
- Site address
- 1750 INLAND ROAD
- City
- ORANGE
- State
- TX
- ZIP
- 77632
- Mailing
- 6540 WEST 9 MILE RD, PENSACOLA, FL 32526
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I
- Issued
- Aug 27, 2015
- Abate by
- Sep 23, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: At the #2 Recovery Boiler Precipitator, NWL model #101659; the employer did not ensure that employees were trained in recognizing the applicable hazardous energy sources or the function of the energy control program, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $7000
- — Z (S) $7000
1910.147 D05 I
- Issued
- Aug 27, 2015
- Abate by
- Sep 23, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices. At the #2 Recovery Boiler Precipitator, NWL model #101659; the employer did not ensure that employees relieved stored energy and rendered safe, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $7000
- — Z (S) $7000
1910.147 D06
- Issued
- Aug 27, 2015
- Abate by
- Sep 23, 2015
- Penalty
- Initial $7,000 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: At the #2 Recovery Boiler Precipitator, NWL model #101659; the employer did not verify the isolation and deenergization prior to starting working on the insulators, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $3500
- — Z (S) $7000
More inspections at Southern Erectors, INC.
View Southern Erectors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340587880.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.