FAIRFIELD, CT —
OSHA Inspection: ROXO'S CONSTRUCTION LLC
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of ROXO'S CONSTRUCTION LLC in 1177 POST ROAD, FAIRFIELD, CT 06824 (NAICS 238140). OSHA activity number 340589050.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROXO'S CONSTRUCTION LLC
- Site address
- 1177 POST ROAD
- City
- FAIRFIELD
- State
- CT
- ZIP
- 06824
- Mailing
- 28 CANFIELD AVENUE, SHELTON, CT 06484
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Sep 16, 2015
- Abate by
- Sep 24, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. WORKPLACE: The employer did not instruct employees in the recognition of hazards associated with operating fuel powered equipment, such as (but not limited to) gasoline powered cutoff saw which emitted carbon monoxide (CO) in enclosed spaces or the procedures necessary to eliminate or minimize those hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1926.57 C
- Issued
- Sep 16, 2015
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1926.57(c): "Design and operation." Exhaust fans, jets, ducts, hoods, separators, and all necessary appurtenances, including refuse receptacles, shall be so designed, constructed, maintained and operated as to ensure the required protection by maintaining a volume and velocity of exhaust air sufficient to gather dusts, fumes, vapors, or gases from said equipment or process, and to convey them to suitable points of safe disposal, thereby preventing their dispersion in harmful quantities into the atmosphere where employees work. WORKSITE: The employer did not ensure through providing not only proper and appropriate ventilation equipment, but also specific instructions that the enclosed basement atmosphere where employees were operating a Stihl Model TS 500i gasoline powered cutoff saw to cut out a large opening in a concrete wall in the basement of a building could have not only appropriate air exchanges, but also the harmful gases were vented out to suitable and safe points. On or about April 7, 2015, the harmful gases (carbon monoxide), emitted from the above cutoff saw while performing the above task vented out to an unsuitable points, exposing the employees working in and around the "points" area to carbon monoxide. The employee were taken to a local hospital for carbon monoxide treatment.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
More inspections in this industry (NAICS 238140)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340589050.