Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOHN J. STEUBY COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOHN J. STEUBY COMPANY in 6002 N. LINDBERGH, HAZELWOOD, MO 63042 (NAICS 332721). OSHA activity number 340593417.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch John J. Steuby Company — free Get an email when a new federal OSHA severe-injury report for John J. Steuby Company is published. One employer, no account, unsubscribe in one click.
Site address
6002 N. LINDBERGH
City
HAZELWOOD
State
MO
ZIP
63042
Mailing
6002 N. LINDBERGH, HAZELWOOD, MO 63042
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332721
Employees
76
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 18, 2015
Abate by
Sep 14, 2015
Penalty
Initial $3,273 · Current $2,291 Reduced
OSH ACT of 1970 Section (5)(a)(1):   Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling from a distance greater than four feet:    Plant: A vehicle-mounted aerial platform with visibly leaking hydraulic fluid which affected the operation of the equipment was not repaired prior to use as required by the Operating Manual in accordance with ANSI A 92.6-1990, Section 8.4.   Two of many methods that can be used to correct the hazard are mentioned below:   01.  Establish a pre-start inspection program as required by the manual.  02.  Remove the aerial platform from service if any problems or malfunctions affect the safe operation of the equipment until the problems or malfunctions are corrected.    DISACLAIMER:   a. The employer is not limited to the abatement methods suggested by OSHA.     b.  The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
  • — I (S) $2291.1
  • — Z (S) $3273

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 18, 2015
Abate by
Sep 4, 2015
Penalty
Initial $3,273 · Current $2,291 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes and fittings were not effectively closed:   Assembly area: An unused electric circuit breaker slot in a panel board was not covered to prevent electrical hazards to employees.
Recent events (2)
  • — I (S) $2291.1
  • — Z (S) $3273

1910.157 C01

Other-than-serious 1 instance 10 exposed
Issued
Aug 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   Assembly area: An un-mounted portable fire extinguisher, blocked by stored materials, was not readily accessible.