MANTOLOKING, NJ —
OSHA Inspection: SCHULER ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCHULER ROOFING, INC. in 966 BARNAGAT LN, MANTOLOKING, NJ 08738 (NAICS 238160). OSHA activity number 340595123.
Where did this inspection happen?
- Establishment
- SCHULER ROOFING, INC.
- Site address
- 966 BARNAGAT LN
- City
- MANTOLOKING
- State
- NJ
- ZIP
- 08738
- Mailing
- 2101 BRIDGE AVE, POINT PLEASANT BORO, NJ 08742
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 15
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.452 J02
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $2310.00 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) Front of house, center, 966 Barnagat Ln: Neither of the two poles used for the aluminum pump jack scaffold were secured at the bottom, nor were any equivalent means used, on or about 04/29/15. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $2310
- — C (S) $3080
- — Z (S) $3080
1926.453 B02 IV
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $2310.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(iv): Employees did not always stand firmly on the floor of the basket, and did not sit or climb on the edge of the basket or use planks, ladders, or other devices for a work position: a) Front of house below peak, 966 Barnagat Ln: Employees climbed the middle and top rails of the Bil-Jax Model 4527A aerial lift when accessing the wall mounted scaffold system approximately 30 feet above ground level, on or about 04/29/15. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (O) $2310
- — C (S) $3080
- — Z (S) $3080
1926.453 B02 V
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and a lanyard attached to the boom or basket when working from an aerial lift: a) Front of house, center, 966 Barnagat Ln: An employee with a fall arrest harness was not attached to the boom or basket while working from the Model 4527 A Bil-Jax aerial lift installing trim approximately 24 feet above ground level, on or about 04/29/2015; b) Front of house, center, 966 Barnagat Ln: An employee was not attached to the boom or basket while using the Model 4527 A Bil-Jax aerial lift while accessing the approximately 30 feet high wall bracket scaffold near the peak of the roof, on or about 04/29/2015. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e). NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (O) $0
- — C (S) $3080
- — Z (S) $3080
1926.454 C
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.454(c): When the employer has reason to believe that an employee lacks the skill or understanding needed for safe work involving the erection, use or dismantling of scaffolds, the employer had not retrained each such employee so that the requisite proficiency is regained: a) 966 Barnagat Ln construction site: Employees need retraining to understand unsafe conditions such as: proper use of fall protection when working from aerial lifts, pump jack scaffolds, and wall bracket scaffolds; need for setting up pole supporting pump jack scaffolds plumb; proper means of accessing scaffold platforms at heights as required by the construction standards; properly securing pump jack poles; on or about 04/29/2015. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $3080
- — Z (S) $3080
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $2310.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 966 Barnagat Ln: Werner aluminum Model D1224-2 Type II extension ladder used by employees to access the approximate 18 foot level scaffold platform extended approximately 2 feet above the level being accessed, on or about 04/29/2015. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (O) $2310
- — C (S) $3080
- — Z (S) $3080
1926.1060 B
- Issued
- Abate by
- Penalty
- Initial $3080.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1060(b): Retraining was not provided for each employee as necessary so that the employee maintains the understanding and knowledge acquired through compliance with this section: a) Construction site, 966 Barnagat Ln: Employees were not using the Werner aluminum Model D1224-2 extension ladder correctly and could not explain what was wrong with the setup; ladder extended approximately 2 feet above the upper surface being accessed; employees were in need of retraining, on or about 04/29/15. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $3080
- — Z (S) $3080
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $6160.00 · Current $4620.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Front of house working below the peak; 966 Barnagat Ln: The wall bracket scaffold, approximately 30 above ground level, did not have any fall protection at the ends of the platform while employees were working from it to install trim, on or about 04/29/15; b) Front of house working below the peak; 966 Barnagat Ln: The aluminum pump jack scaffold with the platform setup approximately 18 feet above ground level did not have any fall protection at the ends of the platform while an employee was working from it to install trim, on or about 04/29/15. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19. Schuler Roofing, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1), which was contained in OSHA inspection number 315281535, citation number 01, item number 002f and was affirmed as a final order on 08/02/2011, with respect to a workplace located on Jersey Avenue Spring Lake, NJ 07762 .
Recent events (3)
- — J (R) $4620
- — C (R) $6160
- — Z (R) $6160
More inspections at SCHULER ROOFING, INC.
BRIELLE, NJ—2011-08-30 00:00:00
SCHULER ROOFING, INC.
SPRING LAKE, NJ—2011-02-17 00:00:00
SCHULER ROOFING INC.
SPRING LAKE, NJ—2008-08-27 00:00:00
SCHULER ROOFING INC.
View SCHULER ROOFING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340595123.