OSHA Inspection: THE ELECTRIC MATERIALS COMPANY

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of THE ELECTRIC MATERIALS COMPANY in 50 SOUTH WASHINGTON STREET, NORTH EAST, PA 16428 (NAICS 331421). OSHA activity number 340596931.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Electric Materials Company — free Get an email when a new federal OSHA severe-injury report for The Electric Materials Company is published. One employer, no account, unsubscribe in one click.
Site address
50 SOUTH WASHINGTON STREET
City
NORTH EAST
State
PA
ZIP
16428
Mailing
50 SOUTH WASHINGTON STREET, NORTH EAST, PA 16428
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331421
Employees
160
Ownership type
A

4 citations on file for this inspection.

1910.106 E02 IV D

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $3,600 · Current $2,150 Reduced
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:    a.) The Electric Materials Company, 50 South Washington Street, North East, PA 16428: Foundry Area - On or about April 29, 2015, and at times prior thereto, employees periodically dispensed a flammable liquid, Top Bond B, from a fifty-five (55) gallon drum into a container.  The flammable liquid was dispensed from the drum through a quarter turn valve and small pipes.
Recent events (2)
  • — I (S) $2150
  • — Z (S) $3600

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $3,600 · Current $2,150 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:     a.) The Electric Materials Company, 50 South Washington Street, North East, PA 16428: DC Caster Area - On or about April 29, 2015, and at times prior thereto, employees were potentially exposed to burn hazards from molten metal while conducting kettle stirring operations.  Aluminized jackets and aprons were not utilized by employees while conducting kettle stirring operations to prevent thermal burns to the torso, arms, and legs.
Recent events (2)
  • — I (S) $2150
  • — Z (S) $3600

1910.132 D01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):   a.) The Electric Materials Company, 50 South Washington Street, North East, PA 16428: DC Caster Area - On or about April 29, 2015, and at times prior thereto, employees were potentially exposed to burn hazards from molten metal while conducting kettle stirring operations.  The hazard assessment did not identify the need for the use of aluminized jackets and aprons for employees conducting kettle stirring operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 2 instances 5 exposed
Issued
Aug 24, 2015
Abate by
Sep 18, 2015
Penalty
Initial $4,500 · Current $2,700 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:     A.) The Electric Materials Company, 50 South Washington Street, North East, PA 16428: Plating Area, Sulfuric Acid Dip Tank Area - On or about April 29, 2015, and at times prior thereto, employees worked with and around corrosive substances including, but not limited to, sulfuric acid and potassium hydroxide.  The eye washes and safety showers in the areas were not inspected weekly to ensure proper operation.      B.) The Electric Materials Company, 50 South Washington Street, North East, PA 16428: Foundry Area - On or about April 29, 2015, and at times prior thereto, employees worked with and around a corrosive liquid, Alpha Set 9040.  Suitable facilities for the quick drenching and flushing of the eyes and body were not available in the area where the corrosive liquid was used.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4500