BRONX, NY —
OSHA Inspection: PRO PRINTING NY.COM, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PRO PRINTING NY.COM, INC. in 2961 ELY AVE., BRONX, NY 10469 (NAICS 323111). OSHA activity number 340604289.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRO PRINTING NY.COM, INC.
- Site address
- 2961 ELY AVE.
- City
- BRONX
- State
- NY
- ZIP
- 10469
- Mailing
- 2961 ELY AVE., BRONX, NY 10469
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 10
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.147 A02 II A
- Issued
- Jun 29, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(a)(2)(ii)(A): Lockout/tagout procedures were not implemented when servicing and/or maintenance was taking place during normal production operations when an employee (s) was required to (A) Remove or bypass a guard or other safety device; (B) were required to place any part of his or her body into area on a machine or piece of equipment where work was actually performed upon the material being processed (point of operation) or where an associated danger zone existed during a machine operating cycle: Pro Printing NY Printing shop a) The employer failed to implement appropriate energy control procedures to protect employees using an UV-Coating (JLG model SGZ-UV740A) machine that was undergoing repairs, where the guard of the pulley and belt have been removed; on or about 02-19-2015. b) The employer failed to implement appropriate energy control procedures to protect employees using an UV-Coating (JLG model SGZ-UV740A) machine that was undergoing repairs, where the employees have been instructed to manually spin an unguarded pulley and belt to "lower" the feeding table; on or about 02-19-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Jun 29, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Pro Printing NY Printing shop a) The employer failed to establish an energy control program (Lock-Out/Tag-Out) to protect employees when conducting activities that expose them to unexpected energization or start up, like unjamming or when working around machines being repaired; on or about 02-19-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I C
- Issued
- Jun 29, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(C): Employees whose work operations were in an area where energy control procedures were utilized were not instructed about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked or tagged: Pro Printing NY Printing shop a) The employer failed to instruct the all employees in the printing "not to operate" the UV-Coating machine (JLG model SGZ-UV740A) which was undergoing repairs and had the guard of the pulley and belt removed while being repaired; on or about 02-19-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F02 I
- Issued
- Jun 29, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(2)(i): When outside servicing personnel were engaged in activities in a facility, the onsite employer and the outside employer did not inform each other of their respective lockout or tagout procedures Pro Printing NY Printing shop a) The employer and outside contractor failed to establish appropriate energy control procedures to protect employees working with and around the UV-Coating machine (JLG model SGZ-UV740A) which was undergoing repairs and had the guard of the pulley and belt removed; on or about 02-19-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03
- Issued
- Jun 29, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3): 29 CFR 1910.219(e)(3): Vertical and inclined belts were not enclosed by a guard conforming to the standards in paragraphs specified in 29 CFR 1910.219(m) and (o): Pro Printing NY Printing shop a) The employer allowed the employees to use an UV-Coating (JLG model SGZ-UV740A) that had the guard of the pulley and belt removed while it was undergoing repairs; on or about 02-19-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jun 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and 04-21-2015 Pro Printing NY Printing shop a) The employer failed to provide appropriate guards to prevent employees contact with rotating parts of the Prism Cutter machine (model QZK-1150 J); on or about 04-21-2015. b) The employer failed to provide appropriate guards to prevent employees contact with rotating parts of the Prism Cutter machine (model QZK-780 NM); on or about 04-21-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jun 29, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) The electrical breaker panel had an unused opening; on or about 04-21-2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.39 A02
- Issued
- Jun 29, 2015
- Abate by
- Jul 10, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. Pro Printing NY Printing shop a) The employer failed to report to OSHA within twenty four (24) hours an amputation suffered by one of its workers; on or about 02-19-2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PRO Printing Ny.Com, INC.
View PRO Printing Ny.Com, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340604289.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.