Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CK PRODUCTS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CK PRODUCTS, LLC in 6510 JIMMY CARTER BLVD SITE C, NORCROSS, GA 30071 (NAICS 424450). OSHA activity number 340604453.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CK Products, LLC — free Get an email when a new federal OSHA severe-injury report for CK Products, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CK PRODUCTS, LLC
Site address
6510 JIMMY CARTER BLVD SITE C
City
NORCROSS
State
GA
ZIP
30071
Mailing
6510 JIMMY CARTER BLVD SITE C, NORCROSS, GA 30071
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424450
Employees
13
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 11 exposed
Issued
Jun 18, 2015
Abate by
Jul 8, 2015
Penalty
Initial $6,300 · Current $3,465 Reduced
OSH ACT of 1970 Section (5)(a)(1): OSH ACT of 1970 Section 5(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards:  On or about 5/1/2015 at 6510 Jimmy Carter Blvd, Suite C in Norcross, GA: The metal storage racks used to store the product and material were not bolted or secured to the floor to prevent the racks from falling on the employees working in the area.  Among one feasible means of abatement would be to follow ANSI standard MH 16.1 2008, Specification for the Design, Testing and Utilization of industrial Steel Storage Racks, paragraph 1.4.7 which states: "The bottom of all columns shall be furnished with column base plates, as specified in Section 7.2. All rack columns shall be anchored to the floor with anchor bolts capable of resisting the forces caused by the horizontal and vertical loads on the rack".
Recent events (2)
  • — I (S) $3465
  • — Z (S) $6300

1910.37 A04

Serious Gravity 5 1 instance 11 exposed
Issued
Jun 18, 2015
Abate by
Jul 8, 2015
Penalty
Initial $3,600 · Current $1,980 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:  On or about 5/1/2015 at 6510 Jimmy Carter Blvd, Suite C in Norcross, GA: The emergency exit lights over the exit doors in the facility were not operating properly to provide the employees lighted access to exit the building safely.  1. Emergency exit light over the exit door in the warehouse area. 2. Emergency exit lights over the exit door in the office and in the hallway of the office area.
Recent events (2)
  • — I (S) $1980
  • — Z (S) $3600

1910.157 E03

Serious Gravity 5 1 instance 11 exposed
Issued
Jun 18, 2015
Abate by
Jul 8, 2015
Penalty
Initial $3,600 · Current $1,980 Reduced
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Note:  Applies to any extinguishers provided in the workplace.   On or about 5/1/2015 at 6510 Jimmy Carter Blvd, Suite C in Norcross, GA: An annual inspection of the portable fire extinguishers located throughout the office and warehouse areas of the facility had not been performed by the employer since March and April 2014 could be ineffective if needed in a fire emergency.
Recent events (2)
  • — I (S) $1980
  • — Z (S) $3600

1910.178 L04 III

Other-than-serious 1 instance 2 exposed
Issued
Jun 18, 2015
Abate by
Jul 8, 2015
Penalty
Initial $900 · Current $495 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  On or about 5/1/2015 at 6510 Jimmy Carter Blvd, Suite C in Norcross, GA: The employees operating the powered industrial truck in the warehouse daily to lift pallets and boxes of products last record of training and reevaluation was May 2011.
Recent events (2)
  • — I (O) $495
  • — Z (O) $900

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340604453.