GEORGETOWN, TX —
OSHA Inspection: TEXAS DISPOSAL SYSTEMS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TEXAS DISPOSAL SYSTEMS in 250 WL WALDEN ROAD, GEORGETOWN, TX 78626 (NAICS 562998). OSHA activity number 340604602.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEXAS DISPOSAL SYSTEMS
- Site address
- 250 WL WALDEN ROAD
- City
- GEORGETOWN
- State
- TX
- ZIP
- 78626
- Mailing
- P.O. BOX 2584, GEORGETOWN, TX 78627
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562998
- Employees
- 33
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.253 B04 III
- Issued
- Jun 2, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about 4 May 2015, and at times prior thereto, Portable Storage Unit #1 had two empty Oxygen cylinders stored within 20 feet of an empty Acetylene cylinder, three full or partially full Propane canisters, a partially full 55-gallon drum of Synthetic Gear Lubricant, and a fall 55-gallon drum of Synthetic Gear Lubricant, exposing the employees working nearby to a struck by, fire and explosion hazard.
Recent events (2)
- — I (S) $1800
- — Z (S) $3000
1910.303 B02
- Issued
- Jun 2, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $2,250 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On or about 4 May 2015, and at times prior thereto, Re-locatable Power Taps (RPTs) were being used in a manner that was not in accordance with the manufacturer's instructions, exposing employees working nearby to a fire hazard. Instance A) Within the administrative building, behind the copier, an RPT was plugged into a Tripp-Lite Uninterruptible Power Supply, which was plugged into a four-plug outlet. The RPT had all six plugs being utilized at the time of the inspection, with one plug having an orange extension cord plugged in. The items plugged into the RPT were mainly for computers and computer accessories. Instance B) Within the administrative building, behind the tablet charging station, a total of four RPTs were plugged into a Panamax Uninterruptible Power Supply, which was plugged into a two-plug wall outlet. The RPT's were providing power to 20 tablet chargers at the time of the inspection. Instance C) Within Portable Storage Unit #3, on the west wall, an RPT was plugged into a three-plug extension cord tree, which was plugged into a two-plug outlet. The RPT was providing power to hand-held tools and chargers at the time of the inspection.
Recent events (2)
- — I (S) $1350
- — Z (S) $2250
1910.303 B07 IV
- Issued
- Jun 2, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. On or about 4 May 2015, and at times prior thereto, the employer allowed damaged electrical equipment to be utilized within the workplace that adversely affected the safe operation or mechanical strength of the unit, exposing employees to an electrical hazard of approximately 120 volts. The unit was a six outlet Belkin Surge Protector, Model F5C047 that had a cracked housing with some degree of separation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 IX
- Issued
- Jun 2, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $2,250 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): All lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. On or about 4 May 2015, and at times prior thereto, within Portable Storage Units #1-3, the overhead fluorescent lights were missing a protective screen or cover allowing the bulbs to be contacted at a height of under 8 feet, exposing the employees working under the lights to the hazard of being struck by falling shards of glass to the skin and eyes.
Recent events (2)
- — I (S) $1350
- — Z (S) $2250
1910.305 B02 I
- Issued
- Jun 2, 2015
- Abate by
- Jun 8, 2015
- Penalty
- Initial $2,250 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose. On or about 4 May 2015, and at times prior thereto, a junction box within Portable Storage Unit #3 was missing the cover allowing the energized wires inside to be contacted, exposing the employees working in the area to an electrical hazard of approximately 120 volts.
Recent events (2)
- — I (S) $1350
- — Z (S) $2250
More inspections at Texas Disposal Systems
View Texas Disposal Systems's full OSHA safety record →
More inspections in this industry (NAICS 562998)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340604602.