EAST AURORA, NY —
OSHA Inspection: RAMSEY RENOVATIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAMSEY RENOVATIONS in 574 MAIN STREET, EAST AURORA, NY 14052 (NAICS 238160). OSHA activity number 340606920.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAMSEY RENOVATIONS
- Site address
- 574 MAIN STREET
- City
- EAST AURORA
- State
- NY
- ZIP
- 14052
- Mailing
- 453 GIRARD AVENUE, EAST AURORA, NY 14052
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 B01 I
- Issued
- May 7, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 5/1/15 at a roofing project located at 574 Main Street, East Aurora, New York; employees were using portable power tools plugged into extension cords. There were no ground fault circuit interrupters or assured equipment grounding conductor program in place. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1926.405 A02 II I
- Issued
- May 7, 2015
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: a) On or about 5/1/15 at a roofing project located at 574 Main Street, East Aurora, New York; extension cords used for portable power tools were on the ground exposed to vehicle traffic without protection from damage. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1200
1926.501 B10
- Issued
- May 7, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) On or about 5/1/15 at a roofing project located at 574 Main Street, East Aurora, New York; employees replacing shingles on a 4 in 12 pitch roof with an eave height of approximately 30 feet were not protected from falling. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
1926.1053 B01
- Issued
- May 7, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 5/1/15 at a roofing project located at 574 Main Street, East Aurora, New York; employees were accessing the roof of a building using extension ladders that had there side rails approximately 6 inches above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2000
More inspections at Ramsey Renovations
View Ramsey Renovations's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340606920.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.