DECATUR, GA ·
OSHA Inspection: EDUARDO CARDENAS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EDUARDO CARDENAS in 2518 PINEVIEW DRIVE, DECATUR, GA 30030 (NAICS 238160). OSHA activity number 340607647.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EDUARDO CARDENAS
- Site address
- 2518 PINEVIEW DRIVE
- City
- DECATUR
- State
- GA
- ZIP
- 30030
- Mailing
- 705 CARIBBEAN DRIVE, FOREST PARK, GA 30297
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.300 B02
- Issued
- May 22, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded: a) 2518 Pineview Drive, Decatur, GA (Jobsite)-The belt and pulley of the compressor that supplies air to the power tools was not guarded on or about 4/14/15. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
1926.501 B13
- Issued
- May 22, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $2,800 · Current $1,952 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) 2518 Pineview Drive, Decatur, GA (Jobsite) - Employees installing felt and composite shingles while working from an unprotected steep 7 inch 12 pitch, sloped roof were exposed to fall hazards of approximately 12-20 feet, on or about 4/14/15. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $1952
- · Z (S) $2800
1926.503 A01
- Issued
- May 22, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) 2518 Pineview Drive, Decatur, GA (Jobsite) - Employee were exposed to fall hazards. The employer failed to develop and implement a fall protection training program to recognize and minimize fall hazards, on or about 04/14/15. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records
Recent events (2)
- · I (S) $1400
- · Z (S) $2000
More inspections in this industry (NAICS 238160)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340607647.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.