KILLEEN, TX —
OSHA Inspection: KILLEEN READY MIX LTD.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KILLEEN READY MIX LTD. in 4101C TRIMMIER RD., KILLEEN, TX 76542 (NAICS 327320). OSHA activity number 340609189.
Where did this inspection happen?
- Establishment
- KILLEEN READY MIX LTD.
- Site address
- 4101C TRIMMIER RD.
- City
- KILLEEN
- State
- TX
- ZIP
- 76542
- Mailing
- P.O. BOX 10759, KILLEEN, TX 76547
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 24
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.23 E02
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.23(e)(2): Stair rails did not consist of a top rail, intermediate rail and/or posts, with the vertical height not more than 34 inches (86.36 cm) nor less than 30 inches (76.2 cm) from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread: (a) Upstairs in the fleet maintenance shop, where employees were using offices and storing truck parts, the stair rail height measured at least 37 inches and the intermediate rail was not positioned approximately halfway between the top rail and riser forward edge, resulting in an opening of at least 20 inches between the top rail and intermediate rail, exposing employees to the hazards of falling as far as 10 feet to the concrete floor. (b) Diesel fueling area in the batch plant yard, where employee(s) were using stairs to access the tank platform for gauging fuel levels in tanks, there was an opening of 30 inches between the top rail and riser leading edge due to lack of an intermediate rail, exposing employees to the hazards of falling as far as 13 feet to the ground. Abatement Note: Reference 1910.23(e)(1) for standard railing specifications.
Recent events (2)
- — I (S) $1400
- — Z (S) $1600
1910.23 E05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
D150
General-duty citation text
29 CFR 1910.23(e)(5)(i): Handrail(s) did not consist of a rounded or other section that would furnish an adequate handhold for anyone grasping it to avoid falling, and the ends of the handrail were not turned in to the supporting wall or otherwise arranged to prevent the ends from becoming a projection hazard: Diesel fueling area in the batch plant yard, where employee(s) were using stairs to access the tank platform for gauging fuel levels in tanks, the top rail was constructed of angle iron with blunt ends projecting beyond the base of the stair posts / ladder side rails, exposing employees to the hazards of falling as far as 13 feet to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.24 D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
D150
General-duty citation text
29 CFR 1910.24(d): Fixed stairways did not have a minimum width of 22 inches: Diesel fueling area in the batch plant yard, where employee(s) were using stairs to access the tank platform for gauging fuel levels in tanks, the stair width measured only 20.25 inches, exposing employees to the hazards of falling as far as 13 feet to the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
2270
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": In the fleet maintenance shop, where employees were using flammable parts washer solvent and performing hot work on trucks, the front door used by employees to exit the building was not posted as an Exit, exposing employees to the hazards of fire.
Recent events (2)
- — I (O) $900
- — Z (S) $1200
1910.37 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
2270
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and was not distinctive in color: (a) In the office building, where employees were working before and/or after daylight hours, Exit signs on 2 side-hinged swinging exit doors to the garage were not lighted or self-luminous, exposing employees to the hazards of fire. (b) In the fleet maintenance shop, where employees were working before and/or after daylight hours, the Exit sign above the side-hinged swinging exit door to the garage was not lighted or self-luminous, exposing employees to the hazards of fire. (c) In the batch plant dispatch building, where employees were working before and/or after daylight hours, Exit signs above two side-hinged swinging doors to the outside were not lighted or self-luminous, exposing employees to the hazards of fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.141 D02 II
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
2270
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: In the fleet maintenance garage, only cold water was provided for hand washing at the lavatory used by employees who were servicing ready mix trucks and using chemicals that were hazardous to skin including, but not limited to, Command High Flash degreaser containing aliphatic petroleum hydrocarbon and 1,3,5-trimethylbenzene, which was used in the parts washer, exposing employees to the hazards of chemical contact, such as skin irritation, dermatitis and defatting of skin.
Recent events (2)
- — I (O) $900
- — Z (S) $1200
1910.146 C02
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $1200.00
0577
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: At the cement batch plant, where employees were mixing concrete and operating ready mix trucks, permit-required confined spaces were not posted, including, but not limited to, bulk silos containing Portland Cement and Fly Ash, the concrete mixer drum, and the cement bag house, exposing employees to the hazards of alkaline dust inhalation and eye contact that could impair ability to self-rescue, including choking and difficulty breathing, and caustic burns to eyes. Abatement Note: A sign reading DANGER-PERMIT-REQUIRED CONFINED SPACE, DO NOT ENTER or using other similar language would satisfy the requirement for a sign.
Recent events (2)
- — I (S) $1200
- — Z (S) $1200
1910.1200 F05 I
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
05772270
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a) In the fleet maintenance garage, the parts washer used by employees while cleaning engine parts with flammable Command High Flash degreaser containing aliphatic petroleum hydrocarbons (Stoddard Solvent) was not labeled with the contents, exposing employees to the hazards of fire and chemical contact, including skin irritation, dermatitis and defatting of skin. (b) At the concrete batch plant, where employees were mixing concrete and operating ready mix trucks, silos containing Portland Cement and Boral Class F Fly Ash (calcium aluminate silicates and crystalline silica) were not labeled with the contents, exposing employees to the hazards of alkaline chemical contact, including alkali burns from contact with Portland Cement.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1910.1200 F05 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
05772270
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) In the fleet maintenance garage, the parts washer used by employees while cleaning engine parts with flammable Command High Flash degreaser containing Stoddard Solvent was not labeled with hazard warnings for the contents, exposing employees to the hazards of fire and chemical contact, such as skin irritation, dermatitis and defatting of skin. (b) At the concrete batch plant, where employees were mixing concrete and operating ready mix trucks, silos containing Portland Cement and Boral Class F Fly Ash (calcium aluminate silicates and crystalline silica) were not labeled with the contents, exposing employees to the hazards of alkaline chemical contact, including alkali burns from contact with Portland Cement. (c) Diesel fueling area in the batch plant yard, where employees were fueling trucks and loaders, and manually gauging fuel levels in the tanks, two tanks containing Diesel Fuel were not labeled with hazard warnings, exposing employees to the hazards of fire, and chemical contact and inhalation, including eye, skin and respiratory irritation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
2270
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use: In the fleet maintenance garage, the employer did not have a material safety data sheet for employees who were using flammable Command High Flash degreaser (aliphatic petroleum hydrocarbons and 1,3,5-trimethylbenzene ) in a parts washer while cleaning engine parts, exposing employees to the hazards of fire and chemical contact, such as skin irritation, dermatitis and defatting of skin.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed to the building: In the fleet maintenance shop, the upstairs storage area was not posted with the floor load limit for employees who were using offices and stocking and retrieving truck parts including, but not limited to, air filters, oil filters, and brake lights.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 327320)
RENO, NV—2026-07-09
R&K READY MIXED CONCRETE, LLC
RENO, NV—2026-07-09
R&K READY MIXED CONCRETE, LLC
MOUNT VERNON, IL—2026-07-08
BEELMAN READY-MIX INC
STOCKTON, CA—2026-07-07
A & A CONCRETE SUPPLY, INC.
LA CROSSE, WI—2026-07-07
RIVER CITY READY MIX, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340609189.