Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INDIAN HEALTH SERVICE, SANITATION FACILITIES CONSTRUCTION, SEATTLE DISTRICT OFFICE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INDIAN HEALTH SERVICE, SANITATION FACILITIES CONSTRUCTION, SEATTLE DISTRICT OFFICE in 701 5TH AVENUE SUITE 1600, SEATTLE, WA 98104 (NAICS 237990). OSHA activity number 340611193.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Indian Health Service, Sanitation Facilities Construction, Seattle District Office — free Get an email when a new federal OSHA severe-injury report for Indian Health Service, Sanitation Facilities Construction, Seattle District Office is published. One employer, no account, unsubscribe in one click.
Site address
701 5TH AVENUE SUITE 1600
City
SEATTLE
State
WA
ZIP
98104
Mailing
701 5TH AVENUE SUITE 1600, MAIL STOP 30, SEATTLE, WA 98104
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
5
Ownership type
D

1 citation on file for this inspection.

1910.303 B02

Repeat Gravity 5 2 instances 3 exposed
Issued
Jun 2, 2015
Abate by
Jul 5, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)  O&M Engineer Cubicle;  A grey power strip was plugged into a white power strip. The UL listing states that relocatable power taps are designed to be plugged into an outlet, and not daisy chained and plugged into other relocatable power taps or extension cords.  This exposes employees to possible electrical fire hazards.  Corrected During Inspection  (b)  A large printer was plugged into a power strip, which was plugged into an extension cord, which was plugged into another power strip. The UL listing states that relocatable power taps are designed to be plugged into an outlet, and not daisy chained and plugged into other relocatable power taps or extension cords.  This exposes employees to possible electrical fire hazards.    The Indian Health Service Seattle District Office was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 98355, citation number 1 item number 1and was affirmed as a final order on October 14, 2011, with respect to a workplace located at Seattle, Washington.
Recent events (1)
  • — Z (R) $0

View Indian Health Service, Sanitation Facilities Construction, Seattle District Office's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340611193.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.