Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A. D. ELECTRIC, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of A. D. ELECTRIC, INC. in 235 SOUTH MONMOUTH ROAD, MONMOUTH, ME 04259 (NAICS 238210). OSHA activity number 340612266.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A. D. Electric, INC. — free Get an email when a new federal OSHA severe-injury report for A. D. Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
235 SOUTH MONMOUTH ROAD
City
MONMOUTH
State
ME
ZIP
04259
Mailing
P.O. BOX 1209, SABATTUS, ME 04280
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.252 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 21, 2015
Abate by
Oct 23, 2015
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.252(a)(1): Fire protection and prevention responsibilities of welders and cutters, their supervisors (including outside contractors) and those in management on whose property cutting and welding was performed, as delineated in the Standard for Fire Prevention in Use of Cutting and Welding Processes, NFPA Standard 51B,1962, which is incorporated by reference as specified in Part 1910.6, were not observed:    235 South Monmouth Road - The employer did not establish an effective fire prevention program associated with welding, cutting and other hot work performed at the establishment.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.252 A02 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 21, 2015
Abate by
Oct 23, 2015
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.252(a)(2)(vii): Combustible materials were not relocated at least 35 feet (10.7 m) from the cutting or welding operation work site, and where relocation was impracticable combustibles were not protected with flameproofed covers:    235 South Monmouth Road - On 5/5/15 at approximately 3:00pm the hydraulic hoses of an Altec boom-supported elevating work platform mounted on a Freightliner truck were not protected from contact with hot welding slag.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.252 A02 IV

Serious Gravity 10 1 instance 3 exposed
Issued
Sep 21, 2015
Abate by
Oct 23, 2015
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.252(a)(2)(iv): Cutting or welding was permitted in areas before the areas were inspected by the individual responsible for authorizing cutting and welding operations:    235 South Monmouth Road - On 5/5/15 at approximately 3:00pm welding was performed on a temporary traffic signal from an Altec boom-supported elevating work platform without the inspection of an individual responsible for authorizing welding operations.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2015
Abate by
Oct 16, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    235 South Monmouth Road - The employer did not ensure that a mechanic who operated the JCB 508 fork truck successfully completed training and evaluation specified in this paragraph (l).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.178 M05 III

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 21, 2015
Abate by
Oct 16, 2015
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.178(m)(5)(iii): Powered industrial truck(s), with the operator dismounted and within 25 feet of the truck still in his view, did not have the load engaging means fully lowered, controls neutralized, and the brakes set to prevent movement:    235 South Monmouth Road - On or about 5/5/15 the load of the JCB 508 lift truck were elevated while an operator was not at the controls.  The load included a welding machine on a pallet on the forks of the truck.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

View A. D. Electric, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340612266.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.