OSHA Inspection: CAMOSY INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAMOSY INCORPORATED in 1000 N. MILWAUKEE AVE., WHEELING, IL 60090 (NAICS 236220). OSHA activity number 340620012.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Camosy Incorporated for free Get an email when a new federal OSHA severe-injury report for Camosy Incorporated is published. One employer, no account, unsubscribe in one click.
Establishment
CAMOSY INCORPORATED
Site address
1000 N. MILWAUKEE AVE.
City
WHEELING
State
IL
ZIP
60090
Mailing
12795 120TH AVE., KENOSHA, WI 53142
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
7
Ownership type
Private (A)

8 citations on file for this inspection.

1926.304 F

Other-than-serious 1 instance 4 exposed
Issued
Jun 30, 2015
Abate by
Jul 7, 2015
Penalty
Initial $4,200 · Current $3,000 Reduced
29 CFR 1926.304(f): Section 4.1.2(a) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not guarded by an automatically adjusting hood which completely encloses that portion of the saw above the table and above the material being cut:      a) On or about May 7, 2015, a Bosch table saw was not equipped with a blade guard when used to rip lumber.      In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (O) $3000
  • · Z (S) $4200

1926.304 F

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jun 30, 2015
Abate by
Jul 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator:   a) On or about May 7, 2015, a Bosch table saw was not equipped with a spreader when used to rip lumber.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.304 F

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jun 30, 2015
Abate by
Jul 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers on dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:   a) On or about May 7, 2015, a Bosch table saw was not equipped with non-kickback fingers or dogs when used to rip lumber.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 B01

Other-than-serious 1 instance 7 exposed
Issued
Jun 30, 2015
Penalty
Initial $4,200 · Current $3,000 Reduced
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed:     a) On or about May 7, 2015, employees were exposed to electrical shock from a live circuit breaker panel that did not have a cover installed.
Recent events (2)
  • · I (O) $3000
  • · Z (S) $4200

1926.405 D

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Jun 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(d): Panelboards mounted in cabinets, cutout boxes or enclosures designed for the purpose were not dead front:   a) On or about May 7, 2015, employees were exposed to electrical shock while in close proximity to a circuit breaker panel that had its cover removed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 G01 II

Deleted Serious Gravity 5 1 instance 7 exposed
Issued
Jun 30, 2015
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.405(g)(1)(ii): Flexible cord was not equipped with an attachment plug and energized from a receptacle outlet when used as permitted in 29 CFR 1926.405(g)(1)(i) [C], [F], or [H]:    a) On or about May 7, 2015, employees were exposed to electrical hazards while using an extension cord to supply power to a miter saw and vacuum cleaner when the cord was hardwired into a breaker panel.     No abatement certification or documentation required for this violation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.405 G02 IV

Other-than-serious 1 instance 7 exposed
Issued
Jun 30, 2015
Penalty
Initial $0 · Current $2,000
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:       On or about May 7, 2015, an extension cord supplying power to a miter saw and a vacuum cleaner was hardwired directly into a circuit breaker panel when no strain relief was provided to prevent strain on the terminal screws.         No abatement certification or documentation required for this violation.
Recent events (2)
  • · I (O) $2000
  • · Z (S) $0

1926.416 E01

Other-than-serious 1 instance 7 exposed
Issued
Jun 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:       a) On and about May 7, 2015, an extension cord that was hardwired into a circuit breaker panel had damage along its length to include cuts and melted areas on the cord jacket.         No abatement certification or documentation required for this violation.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

View Camosy Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340620012.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.