MERIDIAN, ID —
OSHA Inspection: LJ EELLS, CONSTRUCTION, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LJ EELLS, CONSTRUCTION, LLC in 1921 NORTH JUSTINE AVE, MERIDIAN, ID 83642 (NAICS 238350). OSHA activity number 340620590.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LJ EELLS, CONSTRUCTION, LLC
- Site address
- 1921 NORTH JUSTINE AVE
- City
- MERIDIAN
- State
- ID
- ZIP
- 83642
- Mailing
- 15880 CANYON LAKE STREET, CALDWELL, ID 83607
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.100 A
- Issued
- Jun 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Residential jobsite: On May 8, 2015 and at times prior thereto an employee worked on the ground while framing activities were performed overhead, without a hard hat. Note) Certification of corrective action IS required for this item.
Recent events (3)
- — F (S) $1200
- — C (S) $1200
- — Z (S) $1200
1926.304 H01
- Issued
- Jun 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which would meet all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws: a) Residential jobsite: On May 8, 2015 and at times prior thereto employees used a Bosch 4100 table saw without a blade guard in place. Note) Abatement certification IS required for this item.
Recent events (3)
- — F (S) $2000
- — C (S) $2000
- — Z (S) $2000
1926.501 B13
- Issued
- Jun 15, 2015
- Abate by
- Jun 25, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) Residential jobsite: On May 8, 2015 and at times prior thereto an employees performed framing activities on unsheathed trusses, and on the exterior top plate, without a fall protection system in place. Employees were exposed to a 19 foot fall hazard to concrete and the ground below. b) Residential jobsite: On May 8, 2015 and at times prior thereto a guardrail system was not in place around the unprotected edges of the stairway floor opening on the second floor. Employees were exposed to an 8 and a half foot fall hazard to the lower level. c) Residential jobsite: On May 8, 2015 and at times prior thereto guardrail systems were not in place for window and wall openings on the second floor. Employees were exposed to a 13 foot fall hazard to concrete and the ground below. Note) Certification and documentation of corrective actions ARE required for these items
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1926.503 A02 III
- Issued
- Jun 15, 2015
- Abate by
- Jun 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not ensure that each employee had been trained as necessary, by a competent person qualified in the use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used: a) Residential jobsite: On May 8, 2015 and at times prior thereto employees did not recognize or acknowledge the hazards of performing framing activities above 6 feet without any form of fall protection in place. Nor were the employees aware of any actions that could be taken to correct the hazards or minimize their exposure to the hazards. b) Residential jobsite: On May 8, 2015 and at times prior thereto employees did not recognize or acknowledge the hazards of walking and working near an unprotected floor opening. Nor were the employees aware of any actions that could be taken to correct the hazard or minimize their exposure to the hazard. c) Residential jobsite: On May 8, 2015 and at times prior thereto employees did not recognize or acknowledge the hazards of walking and working near unprotected window and wall openings. Nor were the employees aware of any actions that could be taken to correct the hazards or minimize their exposure to the hazards. Note) Certification AND documentation of corrective actions ARE required for these items.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1052 C01 I
- Issued
- Jun 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) Residential jobsite: On May 8, 2015 and at times prior thereto a handrail system was not in place along the stairway used for access to the second floor. Note) Abatement certification IS required for this item.
Recent events (3)
- — F (S) $1200
- — C (S) $1200
- — Z (S) $1200
1926.1052 C01 II
- Issued
- Jun 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one stair rail system along each unprotected side or edge: a) Residential jobsite: On May 8, 2015 and at times prior thereto a stair rail system was not in place along the open sided area of the stairway used for access to the second floor. Note) Certification of corrective action IS required for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at LJ Eells, Construction, LLC
View LJ Eells, Construction, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340620590.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.