Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. ARMY CORPS OF ENGINEERS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of U.S. ARMY CORPS OF ENGINEERS in 701 MILLER AVENUE, HINTON, WV 25951 (NAICS 541330). OSHA activity number 340624774.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Army Corps of Engineers — free Get an email when a new federal OSHA severe-injury report for U.S. Army Corps of Engineers is published. One employer, no account, unsubscribe in one click.
Site address
701 MILLER AVENUE
City
HINTON
State
WV
ZIP
25951
Mailing
701 MILLER AVENUE, HINTON, WV 25951
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541330
Employees
16
Ownership type
D

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.  (a) Hinton: The energy control procedure used for performing maintenance on the elevator car did not address all sources of energy to include, 440v electrical power and gravity of the elevator car, as determined on or about 5/12/2015.  ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed.  (a) Hinton:  Periodic inspections of the energy control procedures were not conducted on processes in which locking out all energy sources is required, such as locking out the elevator car during maintenance activities, as determined on or about 5/12/2015.     ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (S) $0

1910.147 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Hinton: An electrical panel on the 6th floor was not used to isolate and lock out the elevator car prior to performing service and maintenance, as determined on or about 5/12/2015.  ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM.
Recent events (1)
  • — Z (S) $0

1910.146 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit.  (a) Hinton: Maintenance employees periodically enter the elevator shaft, a registered permit-required space to change light bulbs without preparing an entry permit, as determined on or about 5/12/2015.  ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM.
Recent events (1)
  • — Z (S) $0

1910.146 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces.  (a) Hinton: Maintenance employees are not informed of permit required confined spaces, such as elevator shafts prior to entry to perform maintenance activities on the elevator car, as determined on or about 5/12/2015.  ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM.
Recent events (1)
  • — Z (S) $0

1910.146 D06

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 13, 2015
Abate by
Jul 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(6): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations.  (a) Hinton: Maintenance employees periodically enter the elevator shaft, a registered permit-required space to change light bulbs without having at least one assigned attendant outside the space, as determined on or about 5/12/2015.  ABATEMENT CERTIFICATION REQUIRED FOR THIS ITEM
Recent events (1)
  • — Z (S) $0

View U.S. Army Corps of Engineers's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340624774.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.