Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAUGUS CONSTRUCTION CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SAUGUS CONSTRUCTION CORPORATION in 1 FARM LANE, GEORGETOWN, MA 01833 (NAICS 237310). OSHA activity number 340626852.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Saugus Construction Corporation — free Get an email when a new federal OSHA severe-injury report for Saugus Construction Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1 FARM LANE
City
GEORGETOWN
State
MA
ZIP
01833
Mailing
1 FARM LANE, GEORGETOWN, MA 01833
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
19
Ownership type
A

4 citations on file for this inspection.

1910.101 B

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jul 28, 2015
Abate by
Aug 28, 2015
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  (a) Location - Shop:  On or about 5/12/15, the employer failed to secure a cylinder containing acetylene.
Recent events (3)
  • — F (S) $0
  • — C (S) $1600
  • — Z (S) $1600

1910.303 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 28, 2015
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) Location - Shop:    On or about 5/12/15, the employer improperly wired a generator in that a four-wire system was reduced to a 3-wire system and had many deficiencies and electrical hazards.
Recent events (3)
  • — F (S) $2000
  • — C (S) $2800
  • — Z (S) $2800

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 28, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:        (a) Location - Shop:    On or about 5/12/15, the employer failed to ensure that an arc welder/generator was wired so that the path to ground was permanent and continuous.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 28, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:    (a) Location - Shop:    On or about 5/12/15, the employer wired an arc welder/generator with a large splice in the flexible cord.
Recent events (3)
  • — F (S) $0
  • — C (S) $2000
  • — Z (S) $2000

View Saugus Construction Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340626852.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.