YONKERS, NY —
OSHA Inspection: KIM NY CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KIM NY CONSTRUCTION, INC. in 2054 CENTRAL PARK AVE., YONKERS, NY 10710 (NAICS 238140). OSHA activity number 340627579.
Where did this inspection happen?
- Establishment
- KIM NY CONSTRUCTION, INC.
- Site address
- 2054 CENTRAL PARK AVE.
- City
- YONKERS
- State
- NY
- ZIP
- 10710
- Mailing
- 220-55 46TH AVE, #15 R, BAYSIDE, NY 11361
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.21 B02
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: on or about 5/13/15, Central Park Ave. a) The employees were not provided safety and health training as required by the standard.
Recent events (3)
- — R (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.100 A
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: On or about 5/13/2015, Central Park Ave. a) The employees walking and working below the scaffold were not wearing their hard hats.
Recent events (3)
- — R (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.451 B01
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 5/13/15, Central Park Ave. a) The scaffold had two wood planks on the working level and exposed the employee to an 11-12' fall hazard.
Recent events (3)
- — R (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.451 B02
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: On or about 5/13/15, Central Park Ave. a) There was a walkway between both scaffolds. It was not 18" wide.
Recent events (3)
- — R (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.451 C02
- Issued
- Penalty
- Initial $2000.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: On or about 5/13/15, Central Park Ave. a) The scaffold legs rested on cinderblocks and broken pieces of wood.
Recent events (3)
- — R (S) $0
- — C (S) $2000
- — Z (S) $2000
1926.451 G01
- Issued
- Penalty
- Initial $2400.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: On or about 5/13/15, Central Park Ave. a) The 11- 12' high tubular welded frame scaffold did not have standard guardrails.
Recent events (3)
- — R (S) $0
- — C (S) $2400
- — Z (S) $2400
1926.1053 B08
- Issued
- Penalty
- Initial $1200.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: On or about 5/13/2015, Central Park Ave. a) The ladder was not secured and used to gain access to and from the scaffold.
Recent events (3)
- — R (S) $0
- — C (S) $1200
- — Z (S) $1200
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source