Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RW CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RW CORPORATION in 5381 S 108TH STREET, HALES CORNERS, WI 53130 (NAICS 811111). OSHA activity number 340630847.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RW Corporation — free Get an email when a new federal OSHA severe-injury report for RW Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
RW CORPORATION
Site address
5381 S 108TH STREET
City
HALES CORNERS
State
WI
ZIP
53130
Mailing
5381 S 108TH STREET, HALES CORNERS, WI 53130
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
2
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees who operate hydraulic automotive lifts are exposed to struck-by hazards in that automotive lifts can descend without notice.   (a) The employer did not ensure that automotive lifts were functioning in a way so as not to unexpectedly descend when employees are using the lifts to perform various vehicular repair and maintenance. Lifts #1, # 2, and # 5 have known mechanical issues.
Recent events (1)
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) The employer did not ensure that facilities for the flushing of eyes was available for the employees.
Recent events (1)
  • — Z (S) $0

1910.252 A02 XIV A

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Oct 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.252(a)(2)(xiv)(A): The employer did not ensure that the supervisor was responsible for the safe handling of the cutting or welding equipment and the safe use of the cutting or welding process:  (a) The employer did not ensure that an overhead propane valve located near the ceiling between Lift # 1 and # 2 is properly functioning. A clamp tool was used to stop the flow of propane.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half-hour:  (a) The employer did not ensure that oxygen and propane cylinders were not stored together.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) The employer did not ensure that strain relief was present on an electrical cord that supplied power to an overhead light above a work bench.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) The employer did not ensure that a hazard communication program was implemented within the company.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) The employer did not ensure that employees had been provided training on hazard communication.
Recent events (1)
  • — Z (S) $0

1910.1200 G08

Other-than-serious 1 instance 2 exposed
Issued
Oct 7, 2015
Abate by
Nov 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift:  (a) The employer did not ensure that current safety data sheets were maintained.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340630847.