Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AUTONEUM NORTH AMERICA INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AUTONEUM NORTH AMERICA INC. in 645 N. LALLENDORF RD., OREGON, OH 43616 (NAICS 335314). OSHA activity number 340634617.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Autoneum North America INC. — free Get an email when a new federal OSHA severe-injury report for Autoneum North America INC. is published. One employer, no account, unsubscribe in one click.
Site address
645 N. LALLENDORF RD.
City
OREGON
State
OH
ZIP
43616
Mailing
645 N. LALLENDORF RD., OREGON, OH 43616
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335314
Employees
480
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 10 1 instance 15 exposed
Issued
Jul 22, 2015
Abate by
Aug 14, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     a)  On or about May 18, 2015, the employer did not conduct annual audits of its energy control procedure to assure that proper lockout/tagout procedures and requirements were being followed.  The lack of procedure audits exposed employees to injuries in that adequate machine isolation was not being followed when employees accessed hazard areas of machines while performing set up, cleaning and other maintenance activities.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 1 instance 400 exposed
Issued
Jul 22, 2015
Abate by
Aug 14, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):     a)  On or about May 18, 2015, the employer did not assure that employees isolated the 480 volt energy source prior to performing cleaning on the cell#18 singeing operation.  Employees performing the cleaning tasks were exposed to struck by hazards from the robotic arm.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

View Autoneum North America INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340634617.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.