MC KEES ROCKS, PA —
OSHA Inspection: PENNSYLVANIA DRILLING COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PENNSYLVANIA DRILLING COMPANY, INC. in 500 THOMPSON AVENUE, MC KEES ROCKS, PA 15136 (NAICS 332710). OSHA activity number 340640036.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENNSYLVANIA DRILLING COMPANY, INC.
- Site address
- 500 THOMPSON AVENUE
- City
- MC KEES ROCKS
- State
- PA
- ZIP
- 15136
- Mailing
- 500 THOMPSON AVENUE, MC KEES ROCKS, PA 15136
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 26
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C01
- Issued
- Jul 23, 2015
- Abate by
- Sep 9, 2015
- Penalty
- Initial $3,500 · Current $3,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Facility, Mazak Lathe, Serial Number 133241: On or before May 18, 2015, the employer did not institute a Hazardous Energy Control program to prevent incidental contact to employees while removing turnings/chips from the point of operation.
Recent events (2)
- — I (S) $3300
- — Z (S) $3500
1910.212 A01
- Issued
- Jul 23, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $4,900 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Facility, Mazak Lathe, Serial Number 133241: On or before May 15, 2015, employees were not guarded from the turret or the rotating chuck while hand de-burring was performed. (b) Facility, Mazak Lathe, Serial Number 133241: On or before May 15, 2015, employees were not guarded against contact by the turret while pushing the pipe free from the chuck.
Recent events (2)
- — I (S) $4500
- — Z (S) $4900
1904.39 A02
- Issued
- Jul 23, 2015
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: (a) Facility: On May 15, 2015, a directly supervised temporary employee was injured and subsequently hospitalized after they were transported from the facility by ambulance. The employer did not report the hospitalization of the temporarily employee until May 18, 2015.