Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STEVE HOLCOMB ROOFING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STEVE HOLCOMB ROOFING, INC. in 505 POPES BLUFFS TRAIL, COLORADO SPRINGS, CO 80901 (NAICS 238160). OSHA activity number 340641091.

Watch Steve Holcomb Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Steve Holcomb Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
505 POPES BLUFFS TRAIL
City
COLORADO SPRINGS
State
CO
ZIP
80901
Mailing
4813 SPRUCEWOOD DRIVE, COLORADO SPRINGS, CO 80918
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.502 D17

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head.  a)  On or about May 12, 2015, and at times prior, roofing employees did not use body harnesses that had attachment points in the middle of the back, near shoulder level.  Employees used body belts for fall arrest with attachment points at the waist line.
Recent events (1)
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.501(b)(13):  Employee(s) engaged in residential construction activities 6 feet (1.8m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were other provisions of paragraph (b) of this section used to provide an alternative fall protection measure:      a)  On or about May 12, 2015, employees were exposed to falls of greater than 6 feet while they performed roofing work on a two story apartment complex without adequate fall protection measures in place.
Recent events (1)
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340641091.