ROCK TAVERN, NY —
OSHA Inspection: POLICH TALLIX INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of POLICH TALLIX INC in 453 ROUTE 17K, ROCK TAVERN, NY 12575 (NAICS 331513). OSHA activity number 340642867.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POLICH TALLIX INC
- Site address
- 453 ROUTE 17K
- City
- ROCK TAVERN
- State
- NY
- ZIP
- 12575
- Mailing
- 453 ROUTE 17K, ROCK TAVERN, NY 12575
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 75
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 A01
- Issued
- Aug 3, 2015
- Abate by
- Sep 18, 2015
- Penalty
- Initial $2,800 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.23(a)(1): Every stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section on all exposed sides (except at the entrance to the stairway): a) Area over the offices - On or about March 19, 2015, a stairway floor opening did not have a standard railing exposing employees to fall hazards.
Recent events (2)
- — I (S) $1700
- — Z (S) $2800
1910.110 F02 II
- Issued
- Aug 3, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $3,500 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.110(f)(2)(ii): Liquefied petroleum gas container(s) stored inside were located near exits, stairways, or in areas normally used or intended for the safe exit of people: a) Gas Storage Area - On or about May 19, 2015, flammable fuel-gas cylinders of Liquefied Petroleum Gas were stored inside and located next to an exit.
Recent events (2)
- — I (S) $1700
- — Z (S) $3500
1910.253 B04 III
- Issued
- Aug 3, 2015
- Abate by
- Aug 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) Gas Storage Area - On or about May 19, 2015, oxygen cylinders were stored within approximately 4 feet of flammable fuel-gas cylinders of Liquefied Petroleum Gas, and approximately 15 feet away from acetylene cylinders (flammable gas) and other flammable fuel-gas Liquefied Petroleum Gas cylinders.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Aug 3, 2015
- Abate by
- Aug 27, 2015
- Penalty
- Initial $3,500 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Facility - On or about May 12, 2015, employees were exposed to caught-in hazards due to operating a Piranha P90 Ironworker (Serial No. P90- 997) without adequate machine guarding.
Recent events (2)
- — I (S) $1700
- — Z (S) $3500
1910.215 A04
- Issued
- Aug 3, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $2,100 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Facility - On or about May 19, 2015, an employee was exposed to caught-in hazards while using the Dayton Grinder A.C. Motor (Model: 12707, Motor Ref: 60064 - B) to sharpen the metal tip for the welder with the opening measuring approximately 1/4" between the work rest(s) and the grinder wheel.
Recent events (2)
- — I (S) $1700
- — Z (S) $2100
1910.215 B09
- Issued
- Aug 3, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Facility - On or about May 19, 2015, an employee was exposed to struck-by hazards while using the Dayton Grinder A.C. Motor (Model: 12707, Motor Ref: 60064 - B) to sharpen the metal tip for the welder with distance between the wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top measuring to approximately 3/4".
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Aug 3, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $3,500 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Facility - On or about May 19, 2015, employees were using a compressed air blow gun to clean such items as, but not limited to, filings, shavings, chips, and other particles out of the crevices in artwork and moldings with the compressed air being approximately 100 p.s.i. exposing employees to air hazards such as air penetrating the skin and causing internal injuries and blowing items into the employees' eyes.
Recent events (2)
- — I (S) $1700
- — Z (S) $3500
1910.305 B01 II
- Issued
- Aug 3, 2015
- Abate by
- Aug 13, 2015
- Penalty
- Initial $2,100 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Grinding Booth Area - On or about May 19, 2015, there were missing knockout plugs in the wall mounted structure with electricity running from a wall mounted knife-switch box 202 Volt 3-phase power into the electrical controls for the Fan and a light switch.
Recent events (2)
- — I (S) $1500
- — Z (S) $2100
1910.37 B06
- Issued
- Aug 3, 2015
- Abate by
- Aug 20, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) Gas Storage Area - On or about May 19, 2015, an exit sign was not illuminated.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Polich Tallix INC
View Polich Tallix INC's full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340642867.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.