Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TANK PARTNERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TANK PARTNERS, INC. in 501 EAST BAXTER ST, SEGUIN, TX 78155 (NAICS 332420). OSHA activity number 340643584.

Watch Tank Partners, INC. — free Get an email when a new federal OSHA severe-injury report for Tank Partners, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TANK PARTNERS, INC.
Site address
501 EAST BAXTER ST
City
SEGUIN
State
TX
ZIP
78155
Mailing
501 EAST BAXTER ST, SEGUIN, TX 78155
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
50
Ownership type
A

9 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    On or about May 20, 2015, at this site, the employer failed to ensure employees were trained to understand the purpose and function of the energy control program.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.147 C06 I

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   On or about May 20, 2015, at this site the employer failed to conduct a periodic review at least annually of the company energy control procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:    On or about May 20, 2015, at this site the employee(s) will use the fire extinguishers to fight the incipient stage of a fire. The employee(s) did not receive annual refresher training.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    On or about May 20, 2015, at this site, the employer failed to ensure the work rest was no more than one eighth inch. The Black Bull 8 inch bench grinder was missing the work rest. The model number of the bench grinder was MD322OSL.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  On or about May 20, 2015, at this site, the employer failed to ensure the tongue guard was adjusted no more than one fourth inch. The Black Bull 8 inch bench grinder was missing the tongue guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2100.00 · Current $1050.00 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     On or about May 20, 2015, at this site, the employer failed to ensure the breakers supplying power to receptacles for the welders had the legend to identify the breakers.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.303 E01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(e)(1)(ii): 1910.303(e)(1)(ii):  Electric equipment shall not be used unless markings have been placed on equipment such as voltage, current, wattage and other ratings as necessary:  On or about May 20, 2015, at this site, the employer failed to ensure the 480 volt disconnect box  in weld shop area had the voltage marked on the door.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 B01

Serious Gravity 1 5 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(b)(1): Safety signs and tags. Safety signs, safety symbols, or accident prevention tags shall be used where necessary to warn employees about electrical hazards which may endanger them, as required by 1910.145:  On or about May 20, 2015, at this site, the employer failed to ensure the signs indicating the potential for an arc flash hazard could exist and the proper personal protective equipment that should be used. Employees/workers exposed to a potential arc flash.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1785.00 · Current $893.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    On or about May 20, 2015, at this site, the employer failed to ensure the 110/120 volt extension cord supplying power to the Red-D-Arc equipment was in good repair. The outer sheath of the electrical cord was pulled away at the strain relief area. The employee was exposed to a potential electrical shock.
Recent events (2)
  • — I (S) $892.5
  • — Z (S) $1785

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340643584.