Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORCORAN JENNISON MANAGEMENT LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CORCORAN JENNISON MANAGEMENT LLC in 373 1/2 BURROWS STREET, PITTSBURGH, PA 15213 (NAICS 531311). OSHA activity number 340646900.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Corcoran Jennison Management LLC — free Get an email when a new federal OSHA severe-injury report for Corcoran Jennison Management LLC is published. One employer, no account, unsubscribe in one click.
Site address
373 1/2 BURROWS STREET
City
PITTSBURGH
State
PA
ZIP
15213
Mailing
150 MOUNT VERNON STREET, BOSTON, MA 02125
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531311
Employees
21
Ownership type
A

5 citations on file for this inspection.

1910.213 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2015
Penalty
Initial $4,590 · Current $4,590
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  (a) Maintenance Shop, 373 1/2 Burrows Street, Pittsburgh, PA:  On or about April 24, 2015 the Ryobi 10 inch table saw was not guarded by an automatically adjusting hood which completely enclosed the portion of the saw blade above the table and material being cut.  An operator was cutting a piece of wood when a nail inside the piece was struck and was thrown back striking the operator in the face.  There was no guard or hood in place to protect the operator from flying pieces or the rotating blade.
Recent events (1)
  • — Z (S) $4590

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Maintenance Shop, 373 1/2 Burrows Street, Pittsburgh, PA:  On or before 05/20/15 there was no guard in place on the Ryobi 10 inch table saw to protect the operator from contact with the rotating saw blade or flying debris.  Employees use the saw to cut plastic blinds exposing them to potential injury from the rotating blade or flying debris.
Recent events (1)
  • — Z (S) $0

1910.37 A03

Other-than-serious 1 instance 6 exposed
Issued
Jun 8, 2015
Abate by
Jun 18, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  (a) Maintenance Shop, 373 1/2 Burrows Street, Pittsburgh, PA:  On or about 05/20/15 an exit leading into the playground area was blocked by panel doors and was not available for use in the event of an emergency.
Recent events (1)
  • — Z (O) $0

1910.132 D02

Other-than-serious 1 instance 6 exposed
Issued
Jun 8, 2015
Abate by
Jun 25, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  (a) Facility, 280 Burrows Street, Pittsburgh, PA:  On or about 05/20/15 the employer did not complete a written certification verifying that a workplace hazard assessment had been conducted to ensure employees were provided with the proper personal protective equipment.
Recent events (1)
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 1 exposed
Issued
Jun 8, 2015
Abate by
Jul 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a) Facility, 280 Burrows Street, Pittsburgh, PA:  On or about 05/20/15 the employer had not provided a copy of Appendix D, in either written or oral format, to employees who wear N95 particulate respirators when performing work.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340646900.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.